-
- Assaf Kadar, Mohammad M Haddara, Stacy Fan, Shrikant Chinchalkar, Louis M Ferreira, and Nina Suh.
- Division of Orthopedic Surgery, University of Western Ontario, Roth-McFarlane Hand and Upper Limb Center, St Joseph's Health Care, London, Ontario, Canada; Department of Orthopedics, Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
- J Hand Surg Am. 2021 Jun 1; 46 (6): 485-492.
PurposeNormal digital flexion relies on flexor tendon pulleys to convert linear muscular force to angular digital motion. However, there is a growing trend to vent them partially during flexor tendon repair. The objective of this study was to examine the effects of a thermoplastic ring, acting as an external pulley, on flexor tendon biomechanics and finger range of motion (ROM) after pulley venting.MethodsWe tested 15 cadaveric digits using an in vitro active finger motion simulator. We measured loads induced by flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) as well as joint ROM with sequential sectioning of the A2, A3, and A4 pulleys compared with an intact pulley condition. At each stage, external thermoplastic pulley rings were applied snugly over the proximal and middle phalanges to recreate A2 and A4 function, respectively.ResultsAfter complete venting of the A2, A3, and A4 pulleys, proximal interphalangeal joint ROM significantly decreased by 13.4° ± 2.7° and distal interphalangeal joint ROM decreased by 15.8° ± 2.1°. Application of external rings over the proximal and middle phalanx resulted in a residual ROM decrease of 8.3° ± 1.9° at the proximal interphalangeal joint and 7.9° ± 2.1° at the distal interphalangeal joint, nearly restoring ROM. Similarly, complete pulley venting resulted in reduced FDS load by 37% and FDP load by 50% compared with intact pulleys. After application of external rings, loads were restored almost to normal, with a 9% reduction for FDS load and 9% reduction for FDP load compared with intact pulleys.ConclusionsThe application of thermoplastic rings acting as external pulleys is an effective, noninvasive, and reproducible approach to restore flexor tendon biomechanics and digit ROM after pulley venting.Clinical RelevanceThermoplastic rings may be a useful therapeutic adjunct in restoring joint ROM and flexor tendon loads after surgical venting of the pulleys.Copyright © 2021 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.