• Eur Spine J · Apr 2013

    Comparative Study

    Footprint mismatch in total cervical disc arthroplasty.

    • Martin Thaler, Sebastian Hartmann, Michaela Gstöttner, Ricarda Lechner, Michael Gabl, and Christian Bach.
    • Department of Orthopaedic Surgery, Innsbruck Medical University, Anichstr. 35, 6020 Innsbruck, Austria. martin.thaler@uki.at
    • Eur Spine J. 2013 Apr 1;22(4):759-65.

    PurposeCervical disc arthroplasty has become a commonplace surgery for the treatment of cervical radiculopathy and myelopathy. Most manufacturers derive their implant dimensions from early published cadaver studies. Ideal footprint match of the prosthesis is essential for good surgical outcome.MethodsWe measured the dimensions of cervical vertebrae from computed tomography (CT) scans and to assess the accuracy of match achieved with the most common cervical disc prostheses [Bryan (Medtronic), Prestige LP (Medtronic), Discover (DePuy) Prodisc-C (Synthes)]. A total of 192 endplates in 24 patients (56.3 years) were assessed. The anterior-posterior and mediolateral diameters of the superior and inferior endplates were measured with a digital measuring system.ResultsOverall, 53.5 % of the largest device footprints were smaller in the anterior-posterior diameter and 51.1 % in the mediolateral diameter were smaller than cervical endplate diameters. For levels C5/C6 and C6/C7 an inappropriate size match was noted in 61.9 % as calculated from the anteroposterior diameter. Mismatch at the center mediolateral diameter was noted in 56.8 %. Of the endplates in the current study up to 58.1 % of C5/C6 and C6/C7, and up to 45.3 % of C3/C4 and C4/C5 were larger than the most frequently implanted cervical disc devices.ConclusionSurgeons and manufacturers should be aware of the size mismatch in currently available cervical disc prostheses, which may endanger the safety and efficacy of the procedure. Undersizing the prosthetic device may lead to subsidence, loosening, heterotopic ossification and biomechanical failure caused by an incorrect center of rotation and load distribution, affecting the facet joints.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.