• Pol Przegl Chir · May 2015

    Endoscopic Insertion Of A Self-Expandable Stent Combined With Laparoscopic Rinsing Of Peritoneal Cavity As A Method For Staple Line Leaks Treatment In Patients Post Laparoscopic Sleeve Gastrectomy.

    • Maciej Matłok, Piotr Major, Michał Pędziwiatr, Marek Winiarski, Piotr Budzyński, Piotr Małczak, Leif Hynnekleiv, and Andrzej Budzyński.
    • Pol Przegl Chir. 2015 May 1; 87 (5): 238-44.

    UnlabelledCurrently, laparoscopic sleeve gastrectomy is one of bariatric surgeries most commonly performed in the world. The most frequent complications of surgeries of this type, with the highest mortality rate, include bleeding into the GI tract and peritoneal cavity, and sleeve staple line leaks. These severe complications prolong the hospital stay, and often are a cause of patient's death. While in a case of bleeding the procedure appears to be obvious, so far no uniform and standard guidelines have been established for the group of patients with staple line leaks. The aim of the study was to report results of treatment for staple line leaks following laparoscopic sleeve gastrectomy with a laparoscopic procedure and simultaneous endoscopic insertion of a self-expandable stent.Material And Methods152 laparoscopic sleeve gastrectomies were performed from April 2009 to December 2014. The BMI median was 46.9, and the age median was 42 years. Staple line leaks developed in 3 out of 152 people (1.97%). All patients who developed this complication were included in the study. The treatment involved laparoscopic revision surgery with simultaneous endoscopic insertion of a self-expandable stent (Boston Scientific, Wallflex Easophageal Stent, 150×23 mm) into the gastric stump during gastroscopy.ResultsLeaks following laparoscopic sleeve gastrectomy were diagnosed on day 5 after the procedure, on average. Intervention consisting of laparoscopy and endoscopic insertion of a self-expandable stent was initiated within 14 hours of diagnosing the leak, on average. The mean time for which the stent was kept was 5 weeks (4-6 weeks). Stenting proved to be fully effective in all patients, where after discharging home, a cutaneous fistula, periodically (every 2-3 weeks) discharging several millilitres of matter, persisted in one patient. The mean time for the leak healing in 2 patients, in whom the described method was successful in treatment of this complication, was 37 days. No patient died in the perioperative or follow-up period.ConclusionsThe proposed method for treatment of staple line leaks following laparoscopic sleeve gastrectomy by combined laparoscopic rinsing and draining of the peritoneal cavity and endoscopic insertion of a self-expandable stent is an interesting and worth recommending method for treatment of this complication.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…