• Eur Spine J · Mar 2012

    Biomechanical analysis of a new expandable vertebral body replacement combined with a new polyaxial antero-lateral plate and/or pedicle screws and rods.

    • Benjamin Ulmar, Stefanie Erhart, Stefan Unger, Kuno Weise, and Werner Schmoelz.
    • BG Trauma Center, Department of Trauma and Reconstructive Surgery, Eberhard-Karls-University Tübingen, Schnarrenbergstrasse 95, 72076, Tuebingen, Germany.
    • Eur Spine J. 2012 Mar 1; 21 (3): 546553546-53.

    PurposeRestoration of the anterior spinal profile and regular load-bearing is the main goal treating anterior spinal defects in case of fracture. Over the past years, development and clinical usage of cages for vertebral body replacement have increased rapidly. For an enhanced stabilization of rotationally unstable fractures, additional antero-lateral implants are common. The purpose of this study was the evaluation of the biomechanical behaviour of a recently modified, in situ distractible vertebral body replacement (VBR) combined with a newly developed antero-lateral polyaxial plate and/or pedicle screws and rods using a full corpectomy model as fracture simulation.MethodsTwelve human spinal specimens (Th12-L4) were tested in a six-degree-of-freedom spine tester applying pure moments of 7.5 Nm to evaluate the stiffness of three different test instrumentations using a total corpectomy L2 model: (1) VBR+antero-lateral plate; (2) VBR, antero-lateral plate+pedicle screws and rods and (3) VBR+pedicle screws and rods.ResultsIn the presented total corpectomy defect model, only the combined antero-posterior instrumentation (VBR, antero-lateral plate+pedicle screws and rods) could achieve higher stiffness in all three-movement planes than the intact specimen. In axial rotation, neither isolated anterior instrumentation (VBR+antero-lateral plate) nor isolated posterior instrumentation (VBR+pedicle screws and rods) could stabilize the total corpectomy compared to the intact state.ConclusionsFor rotationally unstable vertebral body fractures, only combined antero-posterior instrumentation could significantly decrease the range of motion (ROM) in all motion planes compared to the intact state.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…