• World Neurosurg · Nov 2012

    Randomized Controlled Trial Multicenter Study Comparative Study

    A multicenter, single-blind, prospective randomized trial to evaluate the safety of a polyethylene glycol hydrogel (Duraseal Dural Sealant System) as a dural sealant in cranial surgery.

    • Joshua W Osbun, Richard G Ellenbogen, Randall M Chesnut, Lawrence S Chin, Patrick J Connolly, G Rees Cosgrove, Johnny B Delashaw, John G Golfinos, Jeremy D W Greenlee, Stephen J Haines, Jack Jallo, J Paul Muizelaar, Anil Nanda, Mark Shaffrey, Mitesh V Shah, John M Tew, Harry R van Loveren, Martin E Weinand, Jonathan A White, and James E Wilberger.
    • Department of Neurosurgery, The University of Washington and Harborview Medical Center, Seattle, WA, USA.
    • World Neurosurg. 2012 Nov 1;78(5):498-504.

    ObjectiveIncisional cerebrospinal fluid (CSF) leakage after cranial surgery is a significant cause of morbidity due to poor wound healing and infection, meningitis, and pseudomeningocele formation. Many common dural closure techniques, such as sutures, autologous grafts, gelatin or collagen sponges, and fibrin glues, are used to achieve watertight closure, although none are US Food and Drug Administration approved for this use. DuraSeal Dural Sealant System is a polyethylene glycol (PEG) hydrogel approved by the U.S. Food and Drug Administration for obtaining watertight dural closure when applied after standard dural suturing. This multicenter, prospective randomized study further evaluated the safety of a PEG hydrogel compared with common dural sealing techniques.MethodsA total of 237 patients undergoing elective cranial surgery at 17 institutions were randomized to dural closure augmented with the PEG hydrogel or a control "standard of care" dural sealing technique after Valsalva maneuver demonstrated an intraoperative nonwatertight dural closure. Data were collected on complications resulting in unplanned postoperative interventions or reoperations, surgical site infections, CSF leaks, and other neurological complications within 30 days. Surgeons also provided data on the ease of use of the dural sealing techniques, as well as preparation and application times.ResultsThe incidences of neurosurgical complications, surgical site infections, and CSF leaks were similar between treatment and control groups, with no statistically significant difference between the measures. In the PEG hydrogel group (n = 120), the incidence of neurosurgical complications was 5.8% (n = 7), the incidence of surgical site infections was 1.7% (n = 2), and the incidence of CSF leak was 0.8% (n = 1). In the control group (n = 117), the incidence of neurosurgical complications was 7.7% (n = 9), the incidence of surgical site infection was 2.6% (n = 3), and the incidence of CSF leak was 1.7% (n = 2). Sealant preparation time was less than 5 minutes in 96.6% of the PEG hydrogel group compared with 66.4% of controls (P < 0.001). The dural augmentation was applied in less than 1 minute in 85.7% of the PEG hydrogel group compared with 66.4% of the control group (P < 0.001).ConclusionsThe PEG hydrogel dural sealant used in this study has a similar safety profile to commonly used dural sealing techniques when used as dural closure augmentation in cranial surgery. The PEG hydrogel dural sealant demonstrated faster preparation and application times than other commonly used dural sealing techniques.Copyright © 2012 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.