• Int Orthop · Sep 2017

    Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    • David J Hak, Ryan Fader, Todd Baldini, and Vivek B S Chadayammuri.
    • Department of Orthopedic Surgery, Denver Health Medical Center / University of Colorado, Denver, CO, USA. David.hak@dhha.org.
    • Int Orthop. 2017 Sep 1; 41 (9): 1735-1739.

    PurposeCarbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates.MethodsLocking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded.ResultsShaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p < 0.001). The stiffness and load to failure of shaft locking screws was significantly decreased when inserted 10 degrees off-axis compared to on-axis in CFR-PEEK plates (p < 0.001). Stiffness and load to failure did not vary significantly following screw reinsertion in CFR-PEEK plates.ConclusionThe mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.