• Neuromodulation · Dec 2023

    Feasibility of Spinal Cord Stimulation in Patients With Refractory Angina Pectoris and a Cardiac Implanted Electronic Device.

    • Fabienne E Vervaat, Hans van Suijlekom, and Inge Wijnbergen.
    • Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands. Electronic address: fabienne.vervaat@catharinaziekenhuis.nl.
    • Neuromodulation. 2023 Dec 1; 26 (8): 186718751867-1875.

    ObjectivesFive to 10% of patients with stable coronary artery disease have refractory angina pectoris (RAP). These patients are restricted in performing daily activities due to angina pectoris. Spinal cord stimulation is a last resort treatment option. A number of this patient population also has an indication for a cardiac implanted electronic device (CIED) (pacemaker or implantable cardiac defibrillator). Manufacturers of spinal cord stimulators have stated a warning that interference can occur between the spinal cord stimulator and the CIED. Consequently, only a limited number of patients with RAP and a CIED have received a spinal cord stimulator. The aim of this retrospective cohort study is to determine whether spinal cord stimulation can be safely used in patients with RAP and a CIED.Materials And MethodsAll patients with RAP referred to our center were screened and included if 1) the patient received a spinal cord stimulator as treatment for RAP and if 2) the patient received a CIED either prior to or after spinal cord stimulator implantation. A transcutaneous electrical nerve stimulation (TENS) treadmill test was used as a screening tool to determine whether the patient was eligible for implantation of a spinal cord stimulator. Interference between the spinal cord stimulator and CIED was checked 1) after TENS treadmill test, 2) during implantation of spinal cord stimulator or CIED, 3) during mode switches of the SCS, and 4) during regular out patient follow-up.ResultsIn total, 22 patients had both a spinal cord stimulator and a CIED with an average follow-up duration of 44.5 months. No interference between the spinal cord stimulator and CIED was found.ConclusionSpinal cord stimulation can be safely applied in patients with a CIED provided that the CIED is checked for interference during implantation, if mode switches of the SCS occurred and once yearly after implantation according to routine follow-up.Copyright © 2022 International Neuromodulation Society. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.