• Vet Anaesth Analg · Sep 2011

    Continuous versus intermittent thermodilution for cardiac output measurement during alveolar recruitment manoeuvres in sheep.

    • Tamas D Ambrisko, Paul Coppens, and Yves Moens.
    • Division of Anaesthesiology and perioperative Intensive Care, University of Veterinary Medicine, Veterinärplatz 1, Vienna, Austria. Tamas.Ambrisko@vetmeduni.ac.at
    • Vet Anaesth Analg. 2011 Sep 1; 38 (5): 423-30.

    ObjectiveTo evaluate interchangeability of a thermodilution based STAT mode continuous cardiac output (CCO) measurement method with bolus thermodilution (BTD).Study DesignRandomized crossover study.AnimalsTen 9 month old healthy male sheep.MethodsEach sheep was anaesthetized twice for laparoscopy. On one occasion mechanical ventilation was used immediately after anaesthetic induction (IPPV treatment) and on the other occasion the start of IPPV was delayed and two periods of alveolar recruitment manoeuvres were also performed (RM treatment). Cardiac output (CO) was measured simultaneously with both CCO and BTD at 6 time points. Data were analysed using difference versus mean plots. A priori limits of acceptance were set at ±30% of the mean of every paired measurement. If <5% of the data fell outside of these limits (Chi-square test, p<0.05) the interchangeability of methods was accepted. Proportions of data outside of these limits were also compared between treatments (Fisher's test, p <0.05). Cardiac output data from each treatment and measurement method were also analyzed separately with one-factorial anova and Bonferroni test (p<0.05).ResultsA total of 119 measurements were obtained. Cardiac output ranged from 1.9 to 10.4 L minute(-1) (CCO) and from 1.1 to 9.8 L minute(-1) (BTD). The bias and limits of agreement were 0.5±1.9 L minute(-1) . More than 5% of all data fell outside of the limits of acceptance (24/119), and a larger proportion fell outside of these limits in the RM (20/59) compared to the IPPV treatment (4/60). The Bonferroni test detected significant decreases of CO over time in both treatments when measured with BTD but not with CCO.Conclusions And Clinical RelevanceThe STAT mode CCO method is not interchangeable with BTD during acute haemodynamic changes caused by recruitment manoeuvres, thus the results of STAT mode CCO should be interpreted with caution because decreases in CO may not be detected.© 2011 The Authors. Veterinary Anaesthesia and Analgesia. © 2011 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…