• Eur. J. Clin. Invest. · Sep 2021

    The use of semi-compliant versus non-compliant balloon systems for predilatation during the implantation of self-expandable transcatheter aortic valves: Data from the VIenna CardioThOracic Aortic Valve RegistrY (VICTORY).

    • Markus Mach, Philipp Szalkiewicz, Thomas Poschner, Waseem Hasan, Martin Andreas, Bernhard Winkler, Ena Hasimbegovic, Theresia Steinkellner, Andreas Strouhal, Christopher Adlbrecht, Georg Delle-Karth, and Martin Grabenwöger.
    • Department of Cardiac Surgery, Medical University of Vienna - Vienna General Hospital, Vienna, Austria.
    • Eur. J. Clin. Invest. 2021 Sep 1; 51 (9): e13570.

    BackgroundThis study aimed to evaluate the differences in outcome arising from the use of semi-compliant (SCB) versus non-compliant balloon (NCB) systems for predilatation during self-expanding transcatheter aortic valve replacement (TAVR).Methods251 TAVR procedures with the implantation of self-expanding valves after predilatation were analyzed. SCB systems were used in 166 and NCB systems in 85 patients. The primary endpoint was defined as device success, a composite endpoint comprising the absence of procedural mortality, correct valve positioning, adequate valve performance and the absence of more than a mild paravalvular leak. The secondary endpoints were chosen in accordance with the valve academic research consortium (VARC-2) endpoint definitions.ResultsNo significant differences were observed with regard to procedural device success between the SCB- and NCB cohort (SCB: 142 [85.5%%] vs. NCB: 77 [90.6%]; P = .257). There was a notable difference between the rates of conversion to open surgery and the postdilatation rate, both of which were higher for the NCB group (SCB: 1 [0.6%] vs. NCB: 4 [5.1%]; P = .042; SCB: 30 [18.1%] vs. NCB: 34 [40%]; P < .001). In a multivariate logistic regression analysis, the use of semi-compliant balloon systems for predilatation was associated with a lower risk for postdilatation (OR: 0.296; 95% CI: 0.149-0.588) and conversion to open surgery (OR: 0.205; 95% CI: 0.085-0.493; P = .001) but not for device success.ConclusionWhile the balloon compliance did not affect the procedural mortality, device success or the rate of paravalvular leakage, the use of semi-compliant balloons for predilatation during TAVR should be investigated in larger randomized trials in the light of the lower rates of postdilatation and conversion to open surgery compared to their non-compliant counterparts.© 2021 The Authors. European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…