- H Ruhnke, T Eckey, M K Bohlmann, M P Beldoch, A Neumann, A Agic, J Hägele, K Diedrich, J Barkhausen, and P Hunold.
- Rofo. 2013 Oct 1; 185 (10): 983-91.
PurposeTo evaluate a novel feedback-regulated volumetric sonication method in MRguided HIFU treatment of symptomatic uterine fibroids.Materials And Methods27 fibroids with an average volume of 124.9 ± 139.8 cc in 18 women with symptomatic uterine fibroids were ablated using the new HIFU system Sonalleve (1.5 TMR system Achieva, Philips). 21 myomas in 13 women were reevaluated 6 months later. Standard (treatment) cells (TC) and feedback-regulated (feedback) cells (FC) with a diameter of 4, 8, 12, and 16 mm were used and compared concerning sonication success, diameter of induced necrosis, and maximum achieved temperature. The non-perfused volume ratio (NPV related to myoma volume) was quantified. The fibroid volume was measured before, 1 month, and 6 months after therapy. Symptoms were quantified using a specific questionnaire (UFS-QoL).ResultsIn total, 205 TC and 227 FC were applied. The NPV ratio was 23 ± 15 % (2 – 55). The TC were slightly smaller than intended (-3.9 ± 52 %; range, -100 – 81), while the FC were 20.1 ± 25.3 % bigger (p = 0.02). Feedback mechanism is less diversifying in diameter (p < 0.001). Overall, the FC correlate well with the planned treatment diameter (r = 0.79), other than the TC (r = 0.38). Six months after therapy, the fibroid volume was reduced by 45 ± 21 % (5 – 100) (p = 0.001). The symptoms decreased significantly (p = 0.001). No serious adverse events were recorded.ConclusionUse of volumetric sonication leads to homogenous heating and sufficient necrosis. It is a safe and effective therapy for treating symptomatic uterine fibroids. Successful sonication of feedback cells leads to more contiguous necrosis in diameter
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.