-
J. Cardiovasc. Electrophysiol. · Aug 2015
Multicenter Study Comparative StudyAcute and Long-Term Outcomes of Catheter Ablation of Atrial Fibrillation Using the Second-Generation Cryoballoon versus Open-Irrigated Radiofrequency: A Multicenter Experience.
- Arash Aryana, Sheldon M Singh, Marcin Kowalski, Deep K Pujara, Andrew I Cohen, Steve K Singh, Ryan G Aleong, Rajesh S Banker, Charles E Fuenzalida, Nelson A Prager, Mark R Bowers, André D'Avila, and Padraig Gearoid O'Neill.
- Regional Cardiology Associates and Dignity Health Heart & Vascular Institute, Sacramento, California, USA.
- J. Cardiovasc. Electrophysiol. 2015 Aug 1; 26 (8): 832-839.
IntroductionThere are limited comparative data on catheter ablation of atrial fibrillation (CAAF) using the second-generation cryoballoon (CB-2) versus point-by-point radiofrequency (RF). This study examines the acute/long-term CAAF outcomes using these 2 strategies.Methods And ResultsIn this multicenter, retrospective, nonrandomized analysis, procedural and clinical outcomes of 1,196 patients (76% with paroxysmal AF) undergoing CAAF using CB-2 (n = 773) and open-irrigated, non-force sensing RF (n = 423) were evaluated. Pulmonary vein isolation was achieved in 98% with CB-2 and 99% with RF (P = 0.168). CB-2 was associated with shorter ablation time (40 ± 14 min vs. 66 ± 26 min; P < 0.001) and procedure time (145 ± 49 minutes vs. 188 ± 42 minutes; P < 0.001), but greater fluoroscopic utilization (29 ± 13 minutes vs. 23 ± 14 minutes; P < 0.001). While transient (7.6% vs. 0%; P < 0.001) and persistent (1.2% vs. 0%; P = 0.026) phrenic nerve palsy occurred exclusively with CB-2, other adverse event rates were similar between CB-2 (1.6%) and RF (2.6%); P = 0.207. However, freedom from AF/atrial flutter/tachycardia at 12 months following a single procedure without antiarrhythmic therapy was greater with CB-2 (76.6%) versus RF (60.4%); P < 0.001. While this difference was evident in patients with paroxysmal AF (P < 0.001), it did not reach significance in those with persistent AF (P = 0.089). Additionally, CB-2 was associated with reduced long-term need for antiarrhythmic therapy (16.7% vs. 22.0%; P = 0.024) and repeat ablations (14.6% vs. 24.1%; P < 0.001).ConclusionIn this multicenter, retrospective, nonrandomized study, CAAF using CB-2 coupled with RF as occasionally required was associated with greater freedom from atrial arrhythmias at 12 months following a single procedure without antiarrhythmic therapy when compared to open-irrigated, non-force sensing RF, alone.© 2015 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.