• J Rheumatol · Apr 2006

    Randomized Controlled Trial

    Physician control of needle and syringe during aspiration-injection procedures with the new reciprocating syringe.

    • Wilmer Sibbitt, Randy R Sibbitt, Adrian A Michael, Druce I Fu, Hilda T Draeger, Jon M Twining, and Arthur D Bankhurst.
    • Department of Internal Medicine, Division of Rheumatology, University of New Mexico Health Sciences Center, Albuquerque, New Mexico 87131, USA. wsibbitt@salud.anm.edu
    • J Rheumatol. 2006 Apr 1; 33 (4): 771-8.

    ObjectiveTo evaluate physician control of needle and syringe during aspiration-injection syringe procedures by comparing the new reciprocating procedure syringe to a traditional conventional syringe.MethodsTwenty-six physicians were tested for their individual ability to control the reciprocating and conventional syringes in typical aspiration-injection procedures using a novel quantitative needle-based displacement procedure model. Subsequently, the physicians performed 48 clinical aspiration-injection (arthrocentesis) procedures on 32 subjects randomized to the reciprocating or conventional syringes. Clinical outcomes included procedure time, patient pain, and operator satisfaction. Multivariate modeling methods were used to determine the experimental variables in the syringe control model most predictive of clinical outcome measures.ResultsIn the model system, the reciprocating syringe significantly improved physician control of the syringe and needle, with a 66% reduction in unintended forward penetration (p < 0.001) and a 68% reduction in unintended retraction (p < 0.001). In clinical arthrocentesis, improvements were also noted: 30% reduction in procedure time (p < 0.03), 57% reduction in patient pain (p < 0.001), and a 79% increase in physician satisfaction (p < 0.001). The variables in the experimental system--unintended forward penetration, unintended retraction, and operator satisfaction--independently predicted the outcomes of procedure time, patient pain, and physician satisfaction in the clinical study (p < or = 0.001).ConclusionThe reciprocating syringe reduces procedure time and patient pain and improves operator satisfaction with the procedure syringe. The reciprocating syringe improves physician performance in both the validated quantitative needle-based displacement model and in real aspiration-injection syringe procedures, including arthrocentesis.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…