• Resuscitation · Jul 2021

    Prognostic value of brainstem auditory and visual evoked potentials in cardiac arrest patients with targeted temperature management.

    • Jee Yong Lim, Sang Hoon Oh, Kyu Nam Park, Seung Pill Choi, Joo Suk Oh, Chun Song Youn, Han Joon Kim, Hyo Joon Kim, and Hwan Song.
    • Department of Emergency Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. Electronic address: ny1117@catholic.ac.kr.
    • Resuscitation. 2021 Jul 1; 164: 12-19.

    PurposeWe analysed the prognostic value of somatosensory, brainstem auditory and visual evoked potentials (SSEPs, BAEPs and VEPs, respectively) for outcome prediction in cardiac arrest patients with targeted temperature management (TTM) and assessed whether BAEP and VEP measurements conferred added value to SSEP measurements.MethodsCases with SSEPs and VEPs or BAEPs were reviewed in a TTM registry. We focused on whether the following responses were clearly discernible: N20 for SSEPs, V for BAEPs, and P100 for VEPs. Each type of evoked potential was classified as absent, present or indeterminable. Neurological outcomes after 6 months were dichotomized as good (Cerebral Performance Category [CPC] 1-2) or poor (CPC 3-5).ResultsFrom 185 patients, 185 SSEPs, 172 BAEPs and 178 VEPs were included. None of the patients with a good outcome had absent SSEP, BAEP or VEP responses. Absent SSEP, BAEP and VEP responses yielded sensitivities of 42.3% (95% confidence interval [CI], 33.7-51.3%), 9.4% (95% CI, 4.6-16.7%) and 54.4% (95% CI, 46.0-62.5%) for poor outcomes, respectively. For the overall cohort, the addition of VEP measurements improved the sensitivities of single SSEP measurements (65.8% [95% CI, 57.7-73.3%] versus 36.2% [95% CI, 28.6-44.4%] and multimodal prognostication using SSEPs, brainstem reflex and brain computed tomography (75.7% [95% CI, 68.0-82.3%] versus 60.5% [95% CI, 52.3-68.4%]).ConclusionsThe prognostic value of VEPs was comparable to that of SSEPs, but the use of BAEPs was limited due to their low sensitivity. Additional VEP measurements can reduce prognostic uncertainty.Copyright © 2021 Elsevier B.V. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…