Arch Orthop Trauma Surg · Dec 2022
STRYDE versus PRECICE magnetic internal lengthening nail for femur lengthening.
- Sherif Galal, Jonggu Shin, Peter Principe, Nathan Khabyeh-Hasbani, Rena Mehta, Amber Hamilton, S Robert Rozbruch, and Austin T Fragomen.
- Limb Lengthening and Complex Reconstruction Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, Weill Medical College Cornell University, New York, NY, USA.
- Arch Orthop Trauma Surg. 2022 Dec 1; 142 (12): 355535613555-3561.
IntroductionMagnetic internal lengthening nails (MILNs) have been used for femoral lengthening to avoid complications associated with external fixation. The titanium version of the MILN (PRECICE®) has been in use since 2011 but had limitations (50-75 lb) in post-operative weight bearing. A new stainless-steel version of the MILN (STRYDE®) allows 150-250 lb of post-operative weight bearing. The aim is to compare the outcomes of using these two different MILNs for both unilateral and bilateral femoral lengthening.MethodsA single-center, retrospective cohort study was conducted in which patients' records were reviewed from the period from January 2017 to March 2020. A total of 66 femoral lengthening procedures were included in the study and were divided into two groups: STRYDE® group (30 femora) and PRECICE® group (36 femora). Outcomes assessed were the 6-months post-operative Limb Deformity-Scoliosis Research Society (LD-SRS) Score, adjacent joint range of motion (ROM), average distraction rate, bone healing index (BHI), and complications.ResultsNo statistically significant difference was found between the two groups in regard to the (LD-SRS) score, hip ROM, or knee ROM. Statistically significant differences were found between the two groups in regard to BHI (average of 0.84 months/cm and 0.67 months/cm for STRYDE® and PRECICE®, respectively) and distraction rate (average of 0.6 mm/day and 0.9 mm/day for STRYDE® and PRECICE®, respectively). No mechanical nail complications were reported in the STRYDE® group compared to three events of nail failure in the PRECICE® group. One femur in the PRECICE® group needed BMAC injection for delayed healing compared to four femurs in the STRYDE® group.ConclusionThe STRYDE® MILN yields comparable functional results to those of PRECICE® MILN and shows fewer mechanical nail complications. However, STRYDE® MILN requires a slower distraction rate and yields slower healing (larger BHI).Level Of EvidenceLevel III, Therapeutic study.© 2021. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.