Cochrane Db Syst Rev · Jan 2004
Review Meta AnalysisDual chamber versus single chamber ventricular pacemakers for sick sinus syndrome and atrioventricular block.
- J Dretzke, W D Toff, G Y H Lip, J Raftery, A Fry-Smith, and R Taylor.
- Department of Public Health & Epidemiology, University of Birmingham, Edgbaston, Birmingham, UK, B15 2TT.
- Cochrane Db Syst Rev. 2004 Jan 1; 2004 (2): CD003710CD003710.
BackgroundDual chamber pacing or single chamber atrial pacing ('physiologic' pacing) is believed to have an advantage over single chamber ventricular pacing in that it resembles cardiac physiology more closely by maintaining atrioventricular (AV) synchrony and dominance of the sinus node, which in turn may reduce cardiovascular morbidity and mortality thus contributing to patient survival and quality of life. However, a significant proportion of pacemakers currently implanted are single chamber ventricular pacemakers.ObjectivesThe objective of this review was to assess the short- and long-term clinical effectiveness of dual chamber pacemakers compared to single chamber ventricular pacemakers in adults with AV block, sick sinus syndrome or both. An additional objective was to assess separately any potential differences in effectiveness between dual chamber pacing and single chamber atrial pacing. The clinical effectiveness of single chamber atrial pacing versus single chamber ventricular pacing was not examined.Search StrategyThe Cochrane Controlled Trials Register (The Cochrane Library Issue 3, 2002), MEDLINE (1966 to 2002), EMBASE (1980 to 2002) and the Science Citation Index (1980 to 2002) were searched on 19th August 2002. Citation lists and web sites were checked and researchers in the field contacted.Selection CriteriaParallel group or crossover randomised controlled trials of at least 48 hours duration comparing dual chamber pacing and single chamber ventricular pacing, and investigating cardiovascular morbidity, mortality, patient related quality of life, exercise capacity and complication rates.Data Collection And AnalysisData was extracted onto pre-piloted data extraction forms. Quality assessment was undertaken using a checklist, with a sub-sample of quality data independently extracted by a second reviewer. Where appropriate data was available, meta-analysis was performed. Where meta-analysis was not possible, the number of studies showing a positive, neutral or negative direction of effect and statistical significance were simply counted.Main ResultsFive parallel and 26 crossover randomised controlled trials were identified. The quality of reporting was found to be poor. Pooled data from parallel studies shows a statistically non-significant preference for physiologic pacing (primarily dual chamber pacing) for the prevention of stroke, heart failure and mortality, and a statistically significant beneficial effect regarding the prevention of atrial fibrillation (odds ratio (OR) 0.79, 95% CI 0.68 to 0.93). Both parallel and crossover studies favour dual chamber pacing with regard to pacemaker syndrome (parallel: Peto OR 0.11, 95% CI 0.08 to 0.14; crossover: standardised mean difference (SMD) -0.74, 95% CI - 0.95 to -0.52). Pooled data from crossover studies shows a statistically significant trend towards dual chamber pacing being more favourable in terms of exercise capacity (SMD -0.24, 95% CI -0.03 to -0.45). No individual studies reported a significantly more favourable outcome with single chamber ventricular pacing.Reviewers' ConclusionsThis review shows a trend towards greater effectiveness with dual chamber pacing compared to single chamber ventricular pacing, which supports the current British Pacing and Electrophysiology Group's Guidelines regarding atrioventricular block. Additional randomised controlled trial evidence from ongoing trials in this area will further inform the debate.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.