-
Multicenter Study
Optimal matrix size of chest radiographs for computer-aided detection on lung nodule or mass with deep learning.
- Young-Gon Kim, Sang Min Lee, Kyung Hee Lee, Ryoungwoo Jang, Joon Beom Seo, and Namkug Kim.
- Department of Biomedical Engineering, Asan Institute of Life Science, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea.
- Eur Radiol. 2020 Sep 1; 30 (9): 4943-4951.
ObjectivesTo investigate the optimal input matrix size for deep learning-based computer-aided detection (CAD) of nodules and masses on chest radiographs.MethodsWe retrospectively collected 2088 abnormal (nodule/mass) and 352 normal chest radiographs from two institutions. Three thoracic radiologists drew 2758 abnormalities regions. A total of 1736 abnormal chest radiographs were used for training and tuning convolutional neural networks (CNNs). The remaining 352 abnormal and 352 normal chest radiographs were used as a test set. Two CNNs (Mask R-CNN and RetinaNet) were selected to validate the effects of the squared different matrix size of chest radiograph (256, 448, 896, 1344, and 1792). For comparison, figure of merit (FOM) of jackknife free-response receiver operating curve and sensitivity were obtained.ResultsIn Mask R-CNN, matrix size 896 and 1344 achieved significantly higher FOM (0.869 and 0.856, respectively) for detecting abnormalities than 256, 448, and 1792 (0.667-0.820) (p < 0.05). In RetinaNet, matrix size 896 was significantly higher FOM (0.906) than others (0.329-0.832) (p < 0.05). For sensitivity of abnormalities, there was a tendency to increase sensitivity when lesion size increases. For small nodules (< 10 mm), the sensitivities were 0.418 and 0.409, whereas the sensitivities were 0.937 and 0.956 for masses. Matrix size 896 and 1344 in Mask R-CNN and matrix size 896 in RetinaNet showed significantly higher sensitivity than others (p < 0.05).ConclusionsMatrix size 896 had the highest performance for various sizes of abnormalities using different CNNs. The optimal matrix size of chest radiograph could improve CAD performance without additional training data.Key Points• Input matrix size significantly affected the performance of a deep learning-based CAD for detection of nodules or masses on chest radiographs. • The matrix size 896 showed the best performance in two different CNN detection models. • The optimal matrix size of chest radiographs could enhance CAD performance without additional training data.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.