Eur J Cardiothorac Surg · Jul 2005
Comparative StudyThe sealing effect of fibrin glue against alveolar air leakage evaluated up to 48 h; comparison between different methods of application.
- Masafumi Kawamura, Masatoshi Gika, Yotaro Izumi, Hirohisa Horinouchi, Noriko Shinya, Makio Mukai, and Koichi Kobayashi.
- Division of General Thoracic Surgery, Department of Surgery, Keio University, School of Medicine, 35 Shinanomachi, Shinjuku-Ku, Tokyo, 160-8582 Japan. kawamura@sc.itc.keio.ac.jp
- Eur J Cardiothorac Surg. 2005 Jul 1; 28 (1): 39-42.
ObjectiveThere is little experimental evidence to show how much positive airway pressure fibrin sealants can actually withstand, and in particular, how this effect changes over time. In the present study, we experimentally evaluated the sealing effect of fibrin glue against alveolar air leakage up to 48 h after application.MethodsBeagles were used (n = 48). Under thoracotomy, approximately 5 x 10 mm defects (2 mm depth) were made on the lung surface. Fibrin glue sealants were applied to this defect in three ways. In rubbing and spray method, fibrinogen was rubbed, followed by spraying of both fibrinogen and thrombin solutions. In double layer method, fibrinogen was dripped, followed by thrombin. Collagen fleece, coated with fibrinogen and thrombin (TachoComb) was also tested. The minimum positive airway pressure which produced air leakage was measured for each sealed defect (seal breaking pressure, cmH2O) at 0, 3, 6, 12, 24, and 48 h after application (n = 6 at each time point).ResultsThe seal-breaking pressure increased over time in all of the application methods. At 6 h, differences between methods were not significant but three defects in RS reached 70 cmH2O, the maximum pressure tested, compared with none in other two methods. At 12h, the seal-breaking pressure was significantly higher in RS compared with the other two methods (rubbing and spray method vs TachoComb; 66+/-3 vs 47+/-17, P = 0.047, rubbing and spray method vs double layer method; 66+/-3 vs 42+/-18, P = 0.024). Beyond 24 h, sealing pressure reached close to 70 cmH2O in all the methods.ConclusionsThe results show that the sealing effect of fibrin glue is relatively unstable up to 12h after its application. Rubbing and spray method may help the fibrin seal to reach its full strength faster compared with the other two methods.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.