-
Interact Cardiovasc Thorac Surg · Jan 2020
Five-year follow-up of transvenous and epicardial left ventricular leads: experience with more than 1000 leads.
- Heiko Burger, Simon Pecha, Samer Hakmi, Bastian Opalka, Markus Schoenburg, and Tibor Ziegelhoeffer.
- Department of Heart Surgery, Kerckhoff-Klinik, Bad Nauheim, Germany.
- Interact Cardiovasc Thorac Surg. 2020 Jan 1; 30 (1): 74-80.
ObjectivesTransvenous coronary sinus leads are considered to be the gold standard for cardiac resynchronization therapy (CRT). However, in patients with abnormal coronary vein anatomy, the epicardial leads can be an alternative. Data comparing durability and performance of these 2 lead types are limited. In order to provide clarity, we investigated patients receiving CRT system in our centre.MethodsOne thousand and fifty-three consecutive patients scheduled for CRT implantation were retrospectively analysed. From these, 895 received transvenous coronary sinus and 158 epicardial left ventricular (LV) leads. Lead-specific as well as LV functional parameters have been evaluated in 60 months' follow-up.ResultsTechnical characteristics (pacing threshold, impedance and sensing) of both lead types remained stable during the whole observation period. Whereas an early revision (<6 month) was noted in 5.4% of transvenous leads, no reintervention has been necessary for epicardial leads. During the 5-year observation period, a lead revisions rate of 10.2% for transvenous leads and 1.9% for epicardial leads were detected. Regarding CRT efficacy, excellent results were achieved for both electrode types. In both groups, a statistically significant reduction of New York Heart Association class (2.85-2.13 and 2.96-2.09), increase in left ventricular ejection fraction (24.6-32.6% and 27.2-34.6%), reduction of left ventricular end-systolic diameter/left ventricular end-diastolic diameter and reduction in degree of mitral valve insufficiency could be observed over the time.ConclusionsOur data demonstrate safety and functional efficacy of both transvenous and epicardial leads. Moreover, in long-term follow-up, a commendable durability and performance were found for both lead types. Thus, epicardial leads represent a good alternative when transvenous implantation fails.© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.