• J. Am. Coll. Surg. · Jan 2015

    Comparative Study Clinical Trial

    Transforming hemoglobin measurement in trauma patients: noninvasive spot check hemoglobin.

    • Bellal Joseph, Viraj Pandit, Hassan Aziz, Narong Kulvatunyou, Bardiya Zangbar, Andrew Tang, Terence O' Keeffe, Qasim Jehangir, Kara Snyder, and Peter Rhee.
    • Division of Trauma, Emergency Surgery, Critical Care, and Burns, Department of Surgery, University of Arizona, Tucson, AZ. Electronic address: bjoseph@surgery.arizona.edu.
    • J. Am. Coll. Surg.. 2015 Jan 1;220(1):93-8.

    BackgroundTechnological advances now allow for noninvasive Hbg measurements. Previous studies have reported on the efficacy of continuous noninvasive Hgb devices. Recently, a new device, Pronto-7, a spot check pulse CO-oximeter has become available. The aim of our study was to assess noninvasive Hgb measurement in trauma patients.MethodsWe performed a prospective cohort analysis of all trauma patients presenting to our Level I trauma center. Invasive Hgb and spot check Hgb measurements were obtained simultaneously at presentation. Spot check was measured 2 times with each invasive Hgb value. Normal Hgb was defined as >8 mg/dL. Spearman correlation and Bland-Altman analysis was performed.ResultsA total of 525 patients had attempted spot check Hgb measurements with a success rate of 86% (n = 450). A total of 450 invasive and 1,350 spot check Hgb measurements were obtained. Mean ± SD age was 41 ± 21 years, 74% were male, and mean Injury Severity Score was 21 ± 13. Thirty-eight percent (n = 173) of patients had Hgb ≤8 mg/dL at presentation. Mean invasive Hgb was 11.5 ± 4.36 g/dL, mean spot check Hgb 11.1 ± 3.60 g/dL, and mean difference was 0.3 ± 1.3 g/dL. Spot check Hgb values had strong correlation with invasive Hgb measurements (R(2) = 0.77; R = 0.86; p = 0.04) with 76% accuracy and 95.4% sensitivity.ConclusionsSpot check Hgb monitoring had excellent correlation with invasive Hgb measurements. Application of spot check has more clinical use as compared with previous continuous Hgb monitoring. This novel technology allows immediate and accurate Hgb measurements in trauma patients.Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.