-
- Mateuzs Piotr Kubak, Peter Mæhre Lauritzen, Arne Borthne, Espen Asak Ruud, and Haseem Ashraf.
- 1 Department of Radiology, Akershus University Hospital, Postboks 1000, 1478 Lørenskog, Norway ; 2 Institute of Clinical Medicine, University of Oslo, Akershus University Hospital, Att: Campus Ahus, Postboks 1000, 1478 Lørenskog, Norway ; 3 Department of Pulmonary Medicine, Gentofte University Hospital, Kildegårdsvej 28, 2900 Hellerup, Denmark.
- Ann Transl Med. 2016 Jun 1; 4 (11): 212.
BackgroundAcute pulmonary embolism (APE) is a potentially fatal condition, and making a timely diagnosis can be challenging. Computed tomography pulmonary angiography (CTPA) has become the modality of choice, and this contributes to the increasing load on emergency room CT scanners. Our purpose was to investigate whether an elevated d-dimer cut-off could reduce the demand for CTPA while maintaining a high sensitivity and negative predictive value (NPV).MethodsWe retrospectively reviewed all patients referred for CTPA with suspicion of APE in 2012, and collected d-dimer values and CTPA results. We investigated the diagnostic performance of d-dimer using a 0.5 mg/L cut-off and an age adjusted cut-off. We also evaluated a new and elevated cut-off. Cases were categorized according to their CTPA result into: no embolism, peripheral embolism, lobar embolism and central embolism. Finally we investigated a possible correlation between d-dimer values and location of embolism.ResultsWe included 1,051 CTPAs, from which 216 (21%) showed pulmonary embolism. There were concomitant d-dimer analyses in 822 CTPA examinations. The current 0.5 mg/L cut-off achieved a sensitivity and NPV of 99%. The age-adjusted cut-off achieved a sensitivity and NPV of 98%, and our suggested cut-off of 0.9 mg/L achieved a sensitivity and NPV of 97%.ConclusionsWe conclude that the elevated d-dimer cut-off of 0.9 mg/L achieved a high sensitivity and NPV, while reducing the number of CTPA by 27%. The correlation between d-dimer values and location of embolisms supports the suggestion of an elevated d-dimer value.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.