- Simone Schleger, Markus Kasel, Jayshree Vogel, Michael Lieber, Dietmar Antoni, Ellen Hoffmann, and Walter B Eichinger.
- Department of Cardiac Surgery, Hospital Bogenhausen, Munich, Germany. simone.schleger@klinikum-muenchen.de
- Ann. Thorac. Surg. 2013 Mar 1; 95 (3): 1070-2.
AbstractTranscatheter aortic valve implantation (TAVI) has become an emerging alternative for high-risk patients with aortic stenosis unsuitable for surgical intervention. We report the case of a 26-mm Edwards Sapien valve (Edwards Lifesciences, Irvine, CA) implanted into an insufficient 29-mm CoreValve prosthesis (Medtronic Inc, Minneapolis, MN) 1 year after implantation using the transapical approach in a 59-year-old man. Transesophageal echocardiography showed severe paravalvular regurgitation and computed tomography revealed the CoreValve to be located slightly below the aortic annulus with evidence of underdeployment. The balloon-expandable Sapien system caused a better expansion of the underdeployed CoreValve and the pericardial skirt adequately covered the leakage. The paravalvular regurgitation disappeared and the patient recovered.Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.