• Int J Pharm · Mar 2000

    Comparative Study Clinical Trial

    Comparison of in vitro and in vivo efficiencies of a novel unit-dose liquid aerosol generator and a pressurized metered dose inhaler.

    • S J Farr, S J Warren, P Lloyd, J K Okikawa, J A Schuster, A M Rowe, R M Rubsamen, and G Taylor.
    • Aradigm Corporation, Hayward, CA 94545, USA. farrs@aradigm.com
    • Int J Pharm. 2000 Mar 30; 198 (1): 63-70.

    AbstractGamma scintigraphic imaging was employed in 10 healthy volunteers to compare the total and regional lung deposition of aerosols generated by two delivery platforms that permitted microprocessor-controlled actuation at an optimal point during inhalation. An aqueous solution containing 99mTc-DTPA was used to assess the deposition of aerosols delivered by inhalation from two successive unit-dosage forms (44 microl volume) using a prototype of a novel liquid aerosol system (AERx Pulmonary Delivery System). This was compared with aerosol deposition after inhalation of two 50 microl puffs of a 99mTc-HMPAO-labeled solution formulation from a pressurized metered dose inhaler (MDI). The in vitro size characteristics of the radiolabeled aerosols were determined by cascade impaction. For the AERx system, the predicted lung delivery efficiency based on the product of emitted dose (60.8%, coefficient of variation (CV)=12%) and fine particle fraction (% by mass of aerosol particles <5.7 microm in diameter) was 53.3% (CV=13%). For the solution MDI, the emitted dose was 62.9% (CV=13%) and the predicted lung dose was 44. 9% (CV=15%). The AERx system demonstrated efficient and reproducible dosing characteristics in vivo. Of the dose loaded into the device, the mean percent reaching the lungs was 53.3% (CV=10%), with only 6. 9% located in the oropharynx/stomach. In contrast, the lung deposition from the solution MDI was significantly less (21.7%) and more variable (CV=31%), with 42.0% of the radiolabel detected in the oropharynx/stomach. Analysis of the regional deposition of the radioaerosol indicated a homogeneous pattern of deposition after delivery from the AERx system. A predominantly central pattern of distribution occurred after MDI delivery, where the pattern of deposition was biased towards a central zone depicting the conducting airways. The AERx system, in contrast to MDIs, seems highly suited to the delivery of systemically active agents via pulmonary administration.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.