-
J. Cardiovasc. Electrophysiol. · Jul 2004
Randomized Controlled Trial Comparative Study Clinical TrialOptimization of atrial defibrillation with a dual-coil, active pectoral lead system.
- Eric J Rashba, Stephen R Shorofsky, Robert W Peters, and Michael R Gold.
- Division of Cardiology, University of Maryland School of Medicine, Baltimore, Maryland 21201-1595, USA. erashba@medicine.umaryland.edu
- J. Cardiovasc. Electrophysiol. 2004 Jul 1; 15 (7): 790-4.
IntroductionAtrial defibrillation can be achieved with standard implantable cardioverter defibrillator (ICD) leads, but the optimal shocking configuration is unknown. The objective of this prospective study was to compare atrial defibrillation thresholds (DFTs) with three shocking configurations that are available with standard ICD leads.Methods And ResultsThis study was a prospective, randomized, paired comparison of shocking configurations on atrial DFTs in 58 patients. The lead system evaluated was a transvenous defibrillation lead with coils in the superior vena cava (SVC) and right ventricular apex (RV) and a left pectoral pulse generator emulator (Can). In the first 33 patients, atrial DFT was measured with the ventricular triad (RV --> SVC + Can) and unipolar (RV --> Can) shocking pathways. In the next 25 patients, atrial DFT was measured with the ventricular triad and the proximal triad (SVC --> RV + Can) configurations. Delivered energy at DFT was significantly lower with the ventricular triad compared to the unipolar configuration (4.7 +/- 3.7 J vs 10.1 +/- 9.5 J, P < 0.001). Peak voltage and shock impedance also were significantly reduced (P < 0.001). There was no significant difference in DFT energy when the ventricular triad and proximal triad shocking configurations were compared (3.6 +/- 3.0 J vs 3.4 +/- 2.9 J for ventricular and proximal triad, respectively, P = NS). Although shock impedance was reduced by 13% with the proximal triad (P < 0.001), this effect was offset by an increased current requirement (10%).ConclusionThe ventricular triad is equivalent or superior to other possible shocking pathways for atrial defibrillation afforded by a dual-coil, active pectoral lead system. Because the ventricular triad is also the most efficacious shocking pathway for ventricular defibrillation, this pathway should be preferred for combined atrial and ventricular defibrillators.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.