Bi-level Positive Airway Pressure (BiPAP) with standard exhalation valve does not improve maximum exercise capacity in patients with COPD.
- Ana Maria Moga, Michel de Marchie, Didier Saey, and Jadranka Spahija.
- 1School of Physical and Occupational Therapy, McGill University , Montreal, Quebec , Canada.
- COPD. 2015 Feb 1; 12 (1): 46-54.
BackgroundAlthough BiPAP has been used as an adjunct to exercise, little is know about its effect on exercise in COPD. We aimed to evaluate the acute effect of BiPAP delivered with a standard valve (Vision, Respironics), compared to no assist, on exercise capacity in individuals with COPD.MethodsPeak exercise workload (WLpeak), dyspnea (Borg), end-expiratory lung volume (EELV), tidal volume (VT), minute ventilation (VE), O2 uptake (VO2), and CO2 production (VCO2) were assessed in 10 COPD patients (FEV1 53 ± 22% pred) during three symptom-limited bicycle exercise tests while breathing i) without a ventilator (noPS), ii) with a pressure support (PS) of 0 cm H2O (PS0; IPAP & EPAP 4 cm H2O) and iii) PS of 10 cm H2O (PS10; IPAP 14 & EPAP 4 cm H2O) on separate days using a randomized crossover design.ResultsWLpeak was significantly lower with PS10 (33 ± 16) and PS0 (30.5 ± 13) than noPS (43 ± 19) (p < 0.001). Dyspnea at peak exercise was similar with noPS, PS0 and PS10; at isoload it was lower with noPS compared to PS10 and PS0 (p < 0.01). VT and VE were highest with PS10 and lowest with noPS both at peak exercise and isoload (p < 0.001). EELV was similar at peak exercise with all three conditions. VO2 and VCO2 were greater with PS10 and PS0 than noPS (p < 0.001), both at peak exercise and isoload.ConclusionUse of BiPAP with a standard exhalation valve during exercise increases VT and VE at the expense of augmenting VCO2 and dyspnea, which in turns reduces WLpeak in COPD patients.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.