Nephrol. Dial. Transplant. · Jun 2004
Venography at insertion of tunnelled internal jugular vein dialysis catheters reveals significant occult stenosis.
- Maarten W Taal, Lindsay J Chesterton, and Christopher W McIntyre.
- Department of Renal Medicine, Southern Derbyshire Acute Hospitals NHS Trust, UK. Maarten.Taal@sdah-tr.trent.nhs.uk
- Nephrol. Dial. Transplant. 2004 Jun 1; 19 (6): 1542-5.
BackgroundTunnelled catheters are widely used to provide vascular access for haemodialysis. Percutaneous insertion of these catheters requires large calibre tissue dilators with the potential to cause trauma to central veins, particularly if anatomical abnormalities are present.MethodsWe evaluated the use of venography to identify central vein anatomical abnormalities in 69 consecutive patients undergoing percutaneous placement of tunnelled right internal jugular vein catheters. The internal jugular vein was entered under ultrasound guidance and venography was performed prior to insertion of a guide-wire. Images were evaluated on-screen by the operator and a decision made regarding the need for additional fluoroscopy during insertion of the catheter.ResultsIn 29 cases (42%), venography showed evidence of unexpected stenosis and/or angulation of the central veins of sufficient severity to warrant additional fluoroscopy during insertion of the dilators, or abandonment of the procedure. Patients who had previously had tunnelled internal jugular catheters had more than double the incidence of such abnormalities than those who had not [15/23 (65%) vs 14/46 (30%); P = 0.009]. In two patients the procedure was abandoned due to severe stenosis. No patient suffered central vein trauma or pneumothorax. There were no adverse reactions to contrast injection.ConclusionsVenography performed immediately prior to tunnelled internal jugular dialysis catheter insertion detects unexpected, clinically significant anatomical abnormalities of the central veins in a substantial proportion of patients, particularly those with a history of previous tunnelled catheter insertion. We suggest that the use of venography may help to minimize the risk of complications from this procedure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.