    Randomized double-blind crossover study of alternative stimulator settings in sacral nerve stimulation for faecal incontinence.

    • J Duelund-Jakobsen, T Dudding, E Bradshaw, S Buntzen, L Lundby, S Laurberg, and C Vaizey.
    • Surgical Research Unit, Department of Surgery P, Aarhus University Hospital, Aarhus, Denmark. jakob.jakobsen@ki.au.dk
    • Br J Surg. 2012 Oct 1;99(10):1445-52.

    BackgroundSacral nerve stimulation is an established treatment for faecal incontinence. Nearly half of all patients experience loss of efficacy at some point. Standard reprogramming restores efficacy for some, but not all, patients. This study aimed to determine whether alternative stimulator settings would increase treatment efficacy.MethodsPatients with sustained loss of efficacy were recruited from two international specialist centres. A number of alternative stimulation parameters were tested using a double-blind randomized crossover study design. Stimulation settings tested were pulse frequencies of 6.9 and 31 Hz, and pulse widths of 90 and 330 µs, compared with one standard setting of 14 Hz/210 µs. Treatment efficacy was evaluated using a disease-specific quality-of-life score (Fecal Incontinence Quality of Life Scale, FIQLS) and a bowel habit diary completed before randomization, during the study period and after 3 months of follow-up with one preferred setting.ResultsFifteen patients were analysed. With one preferred setting, three of four subdomains in the FIQLS improved significantly. The mean(s.d.) total number of incontinence episodes dropped from 11.7(10.8) to 4.8(4.5) per 3 weeks (P = 0.011) and improvements were maintained after 3 months of follow-up. Optimal pacemaker settings were individual, but a trend towards highest patient satisfaction and improved treatment outcome was evident for high-frequency stimulation (31 Hz/210 µs), which was preferred by eight of the 15 patients.ConclusionPatients experiencing loss of efficacy can experience improvement if alternative pacemaker settings are tested. High-frequency stimulation (31 Hz/210 µs) was preferred by more than half of the patients, and improved treatment outcome was sustained at 3 months.Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.