BMC emergency medicine · May 2021
Tidal volume according to the 4-point sealing forces of a bag-valve-mask: an adult respiratory arrest simulator-based prospective, descriptive study.
- Dongchoon Uhm and Ajung Kim.
- Department of Emergency Medical Technology, Daejeon University, 62 Daehak-ro, Dong-gu, Daejeon, 34520, Republic of Korea.
- BMC Emerg Med. 2021 May 1; 21 (1): 57.
BackgroundFor adequate ventilation during bag-valve-mask ventilation, rescuers should ensure a proper mask seal using the one-handed or two-handed technique. Little is known about the magnitude of sealing forces of a bag-valve-mask needed for adequate ventilation. This study aimed to explore the effect of the 4-point sealing forces of a bag-valve-mask on tidal volume while using the one-handed technique, focusing on the moderating effect of C length (the distance from the thumb to the index finger in the C shape of the one-hand EC grip).MethodsA prospective, descriptive simulation study was conducted. A convenience sample of 125 undergraduate paramedic students from two universities was recruited. A self-reported questionnaire was used to collect subjective variables. Tidal volumes, 4-point sealing forces of the mask, peak pressure, and C length of the C shape in the one-hand EC grip were measured using the mechanical lung model under a simulated adult respiratory arrest. Hierarchical regression analysis was used to determine the moderating effect of C length on tidal volume in bag-valve-mask ventilation.ResultsThe average C length, peak pressure, and tidal volume were 7.54 (± 1.85) cm, 11.62 (± 5.40) cmH2O, and 321.66 (± 135.18) mL, respectively. The average range of the 4-point sealing forces was 0.03-0.69 N. The apex sealing force was the weakest among the 4-point sealing forces. Hierarchical regression analysis demonstrated that tidal volume accounted for 62.7% of the variance by C length, peak pressure, and apex sealing force during bag-valve-mask ventilation (F = 9.676, p < 0.001). C length moderated the effect of the apex sealing force and peak pressure on the tidal volume, meaning the higher the peak pressure and apex sealing force, the more the tidal volume and the longer the C length.ConclusionThis first simulation study measuring the 4-point sealing forces during bag-valve-mask ventilation provides effective advice that can be adopted in clinical practice without side effects and underpins the importance of continuous retraining and assessment focused on individual physical characteristics, such as C length and bag-valve-mask sealing forces.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.