-
- Patrice Mertl, Remy Philippot, Philippe Rosset, Henri Migaud, Jacques Tabutin, and Denis Van de Velde.
- Orthopaedic Department, CHU Amiens, Amiens, France. mertl.patrice@chu-amiens.fr
- Int Orthop. 2011 Feb 1; 35 (2): 275-82.
AbstractRevision total hip arthroplasty in the setting of a large proximal femoral deficiency or a peri-prosthetic fracture remains a challenging problem. We describe the development, surgical technique and the use of cementless revision stems with distal inter-locking screws to provide immediate stability of the femoral implant. Results were assessed in a large multicentre French study conducted with the french hip and knee surgery society (SFHG). We retrospectively reviewed 725 revisions using interlocking stems from 14 French orthopaedic departments. Seven different stems were used in this series. In-patient records were retrieved, and in addition to demographic data the indication for revision, the preoperative and postoperative PMA and Harris hip scores were documented. The bone deficiency was classified on the basis of the French National Orthopaedic Meeting (SOFCOT) classification. Intraoperative complications and problems if any were retrieved from operative notes. Clinical status and radiographs at the final follow-up were evaluated, paying special attention to the metaphyseal filling index. Average follow-up was 4.5 years. As for the clinical results, the mean Harris hip score at last follow-up was 81. Therefore, it increased by an average of 31 points. Bone reconstruction was assessed on the cortico-medullary index in the metaphyseal area and at mid-shaft increasing from 36 to 45 and 54 to 63, respectively. Radiologically, 637 implants were stable, and 40 demonstrated subsidence. Forty-eight implants have been revised. We found a significant relation between the metaphyseal filling index, the stability of the stem and the quality of bone reconstruction. Results were analysed with respect to three groups of stems: group 1 was a straight, partially HA-coated implant; group 2 was a curved, fully HA-coated implant; and group 3 was a curved, partially-coated implant. Group 1 showed a significantly higher rate of failure when compared with the others types of implants. Group 2 had better functional results than group 3, which in turn reported better results than group 1. With regard to implant fixation, group 2 had significantly better results. Both groups 2 and 3 induced less thigh pain than group 1. The distal interlocking stem has shown promising results for femoral revisions. The advantages are initial axial and rotational stability and consistent bony in-growth owing to hydroxyapatite coating. Distal locked stems are mainly indicated to treat complex femoral revision with severe bone loss and peri-prosthetic fractures.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.