-
IEEE Trans Biomed Eng · Jan 2008
Optimized wavelets for blind separation of nonstationary surface myoelectric signals.
- Dario Farina, Marie-Françoise Lucas, and Christian Doncarli.
- Center for Sensory-Motor Interaction (SMI), Department of Health Science and Technology, Aalborg University, Aalborg, Denmark. df@hst.aau.dk
- IEEE Trans Biomed Eng. 2008 Jan 1; 55 (1): 78-86.
AbstractSurface electromyography (EMG) signals detected over the skin surface may be mixtures of signals generated by many active muscles due to poor spatial selectivity of the recording. In this paper, we propose a new method for blind source separation (BSS) of nonstationary signals modeled as linear instantaneous mixtures. The method is based on whitening of the observations and rotation of the whitened observations. The rotation is performed by joint diagonalization of a set of spatial wavelet distributions (SWDs). The SWDs depend on the selection of the mother wavelet which can be defined by unconstrained parameters via the lattice parameterization within the multiresolution analysis framework. As the sources are classically supposed to be mutually uncorrelated, the design parameters of the mother wavelet can be blindly optimized by minimizing the average (over time lags) cross correlation between the estimated sources. The method was tested on simulated and experimental surface EMG signals and results were compared with those obtained with spatial time-frequency distributions and with second-order statistics (only spectral information). On a set of simulated signals, for 10-dB signal-to-noise ratio (SNR), the cross-correlation coefficient between original and estimated sources was 0.92 +/- 0.07 with wavelet optimization, 0.74 +/- 0.09 with the wavelet leading to the poorest performance, 0.85 +/- 0.07 with Wigner-Ville distribution, 0.86 +/- 0.07 with Choi-Williams distribution, and 0.73 +/- 0.05 with second-order statistics. In experimental conditions, when the flexor carpi radialis and pronator teres were concomitantly active for 50% of the time, crosstalk was 55.2 +/- 10.0% before BSS and was reduced to 15.2 +/- 6.3% with wavelet optimization, 30.1 +/- 15.0% with the worst wavelet, 28.3 +/- 12.3% with Wigner-Ville distribution, 26.2 +/- 12.0% with Choi-Williams distribution, and 35.1 +/- 15.5% with second-order statistics. In conclusion, the proposed approach resulted in better performance than previous methods for the separation of nonstationary myoelectric signals.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.