- Doron J Kahn, Sherry E Courtney, Andrew M Steele, and Robert H Habib.
- Department of Neonatal-Perinatal Medicine, Schneider Children's Hospital, NSLIJHS, New Hyde Park, New York 11040, USA.
- Pediatr. Res. 2007 Sep 1; 62 (3): 343-7.
AbstractNasal continuous-positive-airway-pressure (NCPAP) is popular for infant respiratory support. We compared delivered to intended intra-prong, proximal-airway, and distal-airway pressures using ventilator (V-NCPAP) and bubble (B-NCPAP) devices. Measurements were repeated at five flows (4, 6, 8, 10, and 12 L/min) and three NCPAP (4, 6, and 8 cm H2O) under no, small, and large nares-prong interface leak conditions. With no-leak, delivered B-NCPAP was systematically greater than intended levels at all pressure sites. The corresponding V-NCPAP flow-dependence was none-to-minimal. Prong and intra-airway B-NCPAP overshoots were also observed with small-leak, while only prong B-NCPAP showed a flow-dependent overshoot for large-leak. Leaks did not affect intra-prong V-NCPAP but resulted in progressively lower than desired, flow-independent intra-airway V-NCPAP. We conclude that the self-adjusting capability of ventilators allows closely matched actual versus intended V-NCPAP. Alternatively, for the range of flows used clinically, intra-prong and intra-airway B-NCPAP are systematically higher at increasing flows than operator-intended levels, even when appreciable nares-prong leak is present. Additionally, the oscillations (noise) characterizing B-NCPAP are substantially attenuated between the proximal and distal airways; therefore, it is unlikely that B-NCPAP engenders ventilation or lung recruitment via this phenomenon. Tubing submersion depth for setting the level of B-NCPAP is highly inaccurate, and operators should instead rely on intra-prong pressure measurement.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.