• Spine · Oct 1998

    Safety and accuracy of transarticular screw fixation C1-C2 using an aiming device. An anatomic study.

    • J S Gebhard, R C Schimmer, and B Jeanneret.
    • Lakewood Orthopaedic Clinic, Colorado, USA.
    • Spine. 1998 Oct 15; 23 (20): 2185-9.

    Study DesignIn this anatomic study, the safety and accuracy of C1-C2 transarticular screw placement was tested in a normal anatomic situation in cadaver specimens using a specially designed aiming device.ObjectivesTo assess the safety and accuracy of transarticular screw placement using the technique described by Magerl and a specially designed aiming device.Summary Of Background DataTransarticular C1-C2 screw fixation has been shown to be biomechanically superior to posterior C1-C2 wiring techniques. Several clinical series have been reported in the literature. However, no previous study assessing the accuracy or safety of this technique has been published. Structures at risk are the vertebral arteries, spinal canal, and the occiput-C1 joint.MethodsFive frozen human cadaveric specimens were thawed and instrumented with 10 C1-C2 transarticular screws, according to the technique described by Magerl but using a specially designed aiming device described by the senior author (Jeanneret). After screw placement, the accuracy of screw positioning and the distance of the screws from the spinal canal, vertebral arteries, and atlanto-occipital joint were determined by anatomic dissection and radiographic analysis.ResultsThe structure at greatest risk was the atlanto-occipital joint, with one screw found to be damaging the joint. Vertebral artery or spinal canal penetration was not observed in any of the specimens. Screw length averaged 45 mm and, with proper length, the screw tip was found to be located approximately 7.5 mm behind the anterior tubercle of C1 on lateral radiographs.ConclusionsThis anatomic study demonstrates that C1-C2 transarticular screw fixation can be performed safely in a normal anatomic situation by surgeons who are familiar with the pertinent anatomy. The aiming device allowed safe instrumentation in all patients. In case of an irregular anatomic situation (e.g., congenital abnormalities or trauma), computed tomographic scan with sagittal reconstruction is recommended-in particular, to obtain information about the course of the vertebral artery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…