• IEEE Trans Biomed Eng · Mar 2016

    A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion Artifacts.

    • Emroz Khan, Forsad Al Hossain, Shiekh Zia Uddin, S Kaisar Alam, and Md Kamrul Hasan.
    • IEEE Trans Biomed Eng. 2016 Mar 1; 63 (3): 550-62.

    GoalAlthough photoplethysmographic (PPG) signals can monitor heart rate (HR) quite conveniently in hospital environments, trying to incorporate them during fitness programs poses a great challenge, since in these cases, the signals are heavily corrupted by motion artifacts.MethodsIn this paper, we present a novel signal processing framework which utilizes two channel PPG signals and estimates HR in two stages. The first stage eliminates any chances of a runaway error by resorting to an absolute criterion condition based on ensemble empirical mode decomposition. This stage enables the algorithm to depend very little on the previously estimated HR values and to discard the need of an initial resting phase. The second stage, on the other hand, increases the algorithm's robustness against offtrack errors by using recursive least squares filters complemented with an additional novel technique, namely time-domain extraction.ResultsUsing this framework, an average absolute error of 1.02 beat per minute (BPM) and standard deviation of 1.79 BPM are recorded for 12 subjects performing a run with peak velocities reaching as high as 15 km/h.ConclusionThe performance of this algorithm is found to be better than the other recently reported algorithms in this field such as TROIKA and JOSS.SignificanceThis method is expected to greatly facilitate the presently available wearable gadgets in HR computation during various physical activities.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…