-
J. Cardiovasc. Electrophysiol. · Nov 2006
Comparative StudyTransthoracic tissue Doppler imaging of the atria: a novel method to determine the atrial fibrillation cycle length.
- Mattias Duytschaever, Alex Heyse, Johan de Sutter, Harry Crijns, Thierry Gillebert, Rene Tavernier, and Robert Tieleman.
- Department of Cardiology, University Hospital Ghent, De Pintelaan 185, 9000 Ghent, Belgium. mattias.duytschaever@Ugent.be
- J. Cardiovasc. Electrophysiol. 2006 Nov 1; 17 (11): 1202-9.
BackgroundThe atrial fibrillation cycle length (AFCL) is a critical parameter for the perpetuation and termination of AF. In the present study, we evaluated a new method to measure the AFCL based on transthoracic tissue Doppler imaging (TDI) of the right atrium (RA) and left atrium (LA).MethodsTwenty patients with AF (6 acute AF, 14 persistent or permanent AF) were studied. A quadripolar catheter was positioned at RA or LA to measure AFCL (AFCL(EGM), gold standard). Transthoracic echocardiography (apical 4-chamber view) was used to perform pulsed wave TDI at the free wall of RA or LA. AFCL(TDI) was defined as the time interval between two consecutive positive to negative crossings of the baseline of the atrial time velocity curves. AFCL(EGM) and AFCL(TDI) were measured at baseline and during a 10-minute infusion of flecainide (1.5 mg/kg).ResultsMeasurement of AFCL(TDI) was feasible in all but one patient. At baseline, AFCL(EGM) was 170 +/- 22 ms, AFCL(TDI) 172 +/- 22 ms (difference 2 +/- 5 ms). AFCL(TDI) correlated significantly with AFCL(EGM) (R = 0.91, P < 0.0001). Bland-Altman analysis showed a bias of -2 ms with a 95% limit of agreement between -26 ms and +22 ms. During flecainide, the AFCL(TDI) method yielded an AFCL prolongation from 176 +/- 23 ms at baseline to 279 +/- 68 ms (P < 0.01) after 10 minutes of infusion (57 +/- 26%).Conclusions(1) Tissue Doppler imaging of the atria during transthoracic echocardiography can be used to reliably determine the AFCL during both acute and persistent or permanent AF. (2) Continuous measurement of AFCL with TDI can be used to monitor the effect of antiarrhythmic drugs on atrial rate during AF. (3) This novel method is attractive because of the ease of acquiring the data and its noninvasive character.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.