Interact Cardiovasc Thorac Surg · Jan 2014
Initial experience of pacemaker and implantable cardioverter defibrillator lead extraction with the new GlideLight 80 Hz laser sheaths.
- Samer Hakmi, Simon Pecha, Björn Sill, Beate Reiter, Stephan Willems, Muhammet Ali Aydin, Yalin Yildirim, Hermann Reichenspurner, and Hendrik Treede.
- Department of Cardiovascular Surgery, University Heart Center Hamburg, Hamburg, Germany.
- Interact Cardiovasc Thorac Surg. 2014 Jan 1; 18 (1): 56-60.
ObjectivesLaser lead extraction is a challenging procedure, especially in patients with old or multiple pacemaker (PM) or implantable cardioverter defibrillator (ICD) leads. The mechanical force is a leading cause of complications during the extraction procedure. Use of new laser sheaths, which deliver a rate of 80 pulses per second, may probably reduce intraoperative adverse events by reduction of extraction force.MethodsBetween January 2012 and April 2013, 76 PM and ICD leads were treated in 38 patients using GlideLight 80 Hz laser sheaths. Indications for lead removals were pocket infection (42.1%), septicaemia or endocarditis (23.7%), lead dysfunction (31.6%) and upgrade from PM to ICD (2.6%). Data on procedural success rates, intra- and postoperative outcomes, as well as 30-day mortality were collected into a database and analysed retrospectively.ResultsThe mean patient age was 62.0 ± 17.7 years (range 18-83), and 73.7% were male. The mean time from initial lead implantation was 96.0 ± 58.3 months (range 24-288). Thirty-seven (48.7%) PM and 39 (51.3%) ICD leads had to be extracted. The mean procedural time was 68.3 ± 27.3 min (range 35-115). Seventy-two of 76 leads (94.8%) were completely removed, partial removal was achieved in 2 (2.6%) leads and a failure of extraction occurred in 2 (2.6%) leads. The overall complication rate was 5.2%, including one major (superior vena cava perforation) (2.6%) and one minor (pocket haematoma) (2.6%) complication. No death occurred during the 30-day follow-up.ConclusionsThe GlideLight 80 Hz laser sheath allows safe and effective removal of chronically implanted PM and ICD leads, combining high procedural success with low complication rates.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.