• Thorac Cardiovasc Surg · Oct 2020

    Comparative Study

    Hemodynamic Comparison of Sutureless and Rapid-Deployment Valves with Conventional Bioprostheses.

    • Max Gotzmann, Manuel Wilbring, Efstratios Charitos, Hendrik Treede, and Miriam Silaschi.
    • Department of Cardiac Surgery, Mid-German Heart Center, Halle (Saale), Germany.
    • Thorac Cardiovasc Surg. 2020 Oct 1; 68 (7): 584-594.

    BackgroundSutureless and rapid-deployment bioprostheses (RPDs) are advantageous due to shorter aortic cross-clamp times (ACCs); however, few studies have investigated hemodynamic outcomes in comparison to conventional bioprostheses (CBs).MethodsAll patients receiving the Perceval (LivaNova, London, United Kingdom) and Intuity (Edwards Lifesciences, Irvine, California, United States) valves from February 2016 to December 2017 were included (n = 61). For controls, patients who underwent aortic valve replacement using CB from 2015 to 2018 (n = 743) were propensity-matched (n = 108). Primary end points were mean gradient at discharge, true internal diameter (ID) after implantation, and paravalvular leakage. Secondary end points were ACCs, cardiopulmonary bypass times (CPBTs), mortality, and pacemaker implantation.ResultsAge was 73.2 years (standard deviation [SD]: 7.6) in the RPD group and 72.9 years (SD: 7.3) in the CB group (p = 0.827). Median logistic EuroSCORE II was 3.4% (Q1: 2; IQ3: 5.3) and 3% (Q1: 1.9; IQ3: 5.6; p = 0.599). While ACCs and CPBT were shorter in RPDs (97 [SD: 31.4] vs. 125.4 minutes [SD: 62.1], p = 0.003; and 76.1 [SD: 25.7] vs. 89.7 minutes [SD: 34.3], p = 0.022), procedural times were similar (p = 0.257). True ID was 21.97 mm (SD: 1.79) in RPDs and 20.15 mm (SD: 1.70) in CB (p < 0.001).RPDs and CB resulted in comparable mean gradients (12.8 mm Hg [SD: 6.4] vs. 13.8 mm Hg [SD: 5.6]; p = 0.387) and rate of paravalvular regurgitation. There were no differences in the rates of pacemaker implantation and mortality.In a subanalysis of RPDs, mean gradient was 15.48 mm Hg (SD: 7.51) in Perceval (n = 21) and 10.79 mm Hg (SD: 4.78) in Intuity (n = 33; p = 0.010).ConclusionsRPDs provided comparable hemodynamic performance, although implanted valves were larger in true ID. Whether this provides superior hemodynamic performance during exercise and longer durability needs further investigation. Among RPDs, the Intuity valve provided lower mean gradients at rest than Perceval valve.Thieme. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…