-
- Rimal H Dossani, Muhammad Waqas, Ammad A Baig, Justin M Cappuzzo, Daniel Popoola, Hamid Rai, Andre Monteiro, Aaron Levy, Eisa Hashmi, Jason M Davies, Elad I Levy, and Adnan H Siddiqui.
- Department of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, State University of New York at Buffalo, Buffalo, New York, USA; Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA.
- World Neurosurg. 2021 Aug 1; 152: e144-e148.
BackgroundThe use of balloon guide catheters (BGCs) for proximal flow arrest during neurointerventional procedures has been limited owing to the incompatibility of BGCs with large-bore aspiration catheters and difficulty in device navigation. The objective of our study was to describe the use of the Walrus catheter (Q'Apel Medical, Fremont, California, USA), a new 8F BGC, with a variety of aspiration catheters and procedures requiring flow arrest.MethodsConsecutive cases using Walrus BGCs for proximal flow arrest during mechanical thrombectomy for acute stroke cases were recorded. The procedure indication, vessel occlusion site, technique, first-pass effect (modified thrombolysis in cerebral infarction score of 2C or 3 after the first recanalization attempt), and complications were recorded and evaluated statistically.ResultsOur study included 57 patients who had undergone mechanical thrombectomy. In addition to mechanical thrombectomy, the Walrus BGC was used in conjunction with the following techniques: stent retrieval in 2 patients (3.5%), stent retrieval followed by aspiration (Solumbra technique) in 41 (71.9%), and aspiration followed by stent retrieval in 14 patients (24.6%). Eight different aspiration catheters were used in 56 of these 57 procedures. The first-pass effect (modified thrombolysis in cerebral infarction score of 2C and 3) was achieved in 36 (63.2%) of 57 procedures. Two patients (3.5%) had experienced intraoperative complications (symptomatic intracerebral hemorrhage) and one patient (1.8%) had died in-hospital.ConclusionsOur results have demonstrated that the Walrus BGC is a highly navigable 8F guide catheter compatible with most available aspiration catheters. Owing to its compatibility with most available aspiration catheters and ease of use, the Walrus BGC is a valuable addition to the tools available for mechanical thrombectomy.Copyright © 2021 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.