Anaesthesiol Intensive Ther · Jan 2019
Randomized Controlled Trial Comparative StudyPerformance of first and second generation supraglottic airway devices in patients with simulated difficult airway: a randomised controlled trial.
- Ergul Yildiz, Kemal Saracoglu, Ayten Saracoglu, Massimiliano Sorbello, Deniz Kizilay, and Haluk Kafali.
- Department of Anaesthesiology and Intensive Care, Istanbul Bilim University, Turkey.
- Anaesthesiol Intensive Ther. 2019 Jan 1; 51 (5): 373-379.
BackgroundGuidelines for management of unanticipated difficult intubation recommend the use of supraglottic airway devices (SADs) in cases of failed intubation. How-ever, there is a lack of comparative studies for different type of devices. In this randomised controlled trial, the performance of 1st and 2nd generation supraglottic airway devices was compared in patients with a simulated difficult airway.Material And MethodsWe enrolled 90 patients, scheduled for elective surgery and suitable for supraglottic airway device insertion. Laryngeal mask airway (LMA)-classic (LMAC), LMA-proseal (LMAP) and LMA-flexible (LMAF) were evaluated. The modified Mallampati test was used for the preoperative airway assessment. Maximal mouth opening, body mass index, thyromental and sternomental distances, and neck circumference were measured, and patients with predicted difficulty were excluded. Insertion time, ease of insertion, oropharyngeal leak pressure, and Brimacombe and Berry Bronchoscopy Scores were evaluated. Peak airway pressure was measured at 1, 15 and 60 min following the insertion of SADs. Complications were recorded.ResultsOropharyngeal leak pressures were 35.2 ± 8.1, 31.7 ± 7.7 and 31.3 ± 6.0 mm Hg for LMAP, LMAC and LMAF respectively (P = 0.079). First min peak airway pressure values were 14.0 ± 4.2, 15.0 ± 3.9, 14.9 ± 4.4 mm Hg respectively (P = 0.403). There was a significant positive correlation between oropharyngeal leak pressure and first min peak airway pressure (r = 0.264, P = 0.013). Mean number of attempts was 1.1 ± 0.3 times (P = 0.840). Insertion time was 20.0 ± 10.4, 17.0 ± 5.7 and 16.4 ± 10.2 s respectively (P = 0.440). Ease of insertion score was 2.0 ± 0.9, 2.1 ± 0.9 and 2.1 ± 1.3 respectively (P = 0.837). There was no significant difference for optimization manoeuvre requirement or fibreoptic scope grades (P = 0.265, P = 0.651, respectively).ConclusionsFirst and second generation of supraglottic airway devices provided similar clinical performance for patients with difficult airway and trauma due to limited cervical motion.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.