• Neonatology · Jan 2012

    Intermittent detection of fetal heart rate abnormalities identify infants at greatest risk for fresh stillbirths, birth asphyxia, neonatal resuscitation, and early neonatal deaths in a limited-resource setting: a prospective descriptive observational study at Haydom Lutheran Hospital.

    • Langli Ersdal Hege H Department of Anaesthesiology and Intensive Care, Stavanger University Hospital, Stavanger, Norway. lehe@sus.no, Estomih Mduma, Erling Svensen, Johanne Sundby, and Jeffrey Perlman.
    • Department of Anaesthesiology and Intensive Care, Stavanger University Hospital, Stavanger, Norway. lehe@sus.no
    • Neonatology. 2012 Jan 1; 102 (3): 235-42.

    BackgroundIntermittent fetal heart rate (FHR) monitoring during labor using an acoustic stethoscope is the most frequent method for fetal assessment of well-being in low- and middle-income countries. Evidence concerning reliability and efficacy of this technique is almost nonexistent.ObjectivesTo determine the value of routine intermittent FHR monitoring during labor in the detection of FHR abnormalities, and the relationship of abnormalities to the subsequent fresh stillbirths (FSB), birth asphyxia (BA), need for neonatal face mask ventilation (FMV), and neonatal deaths within 24 h.MethodsThis is a descriptive observational study in a delivery room from November 2009 through December 2011. Research assistants/observers (n = 14) prospectively observed every delivery and recorded labor information including FHR and interventions, neonatal information including responses in the delivery room, and fetal/neonatal outcomes (FSB, death within 24 h, admission neonatal area, or normal).Results10,271 infants were born. FHR was abnormal (i.e. <120 or >160 beats/min) in 279 fetuses (2.7%) and absent in 200 (1.9%). Postnatal outcomes included FSB in 159 (1.5%), need for FMV in 695 (6.8%), BA (i.e. 5-min Apgar score <7) in 69 (0.7%), and deaths in 89 (0.9%). Abnormal FHR was associated with labor complications (OR = 31.4; 95% CI: 23.1-42.8), increased need for FMV (OR = 7.8; 95% CI: 5.9-10.1), BA (OR = 21.7; 95% CI: 12.7-37.0), deaths (OR = 9.9; 95% CI: 5.6-17.5), and FSB (OR = 35; 95% CI: 20.3-60.4). An undetected FHR predicted FSB (OR = 1,983; 95% CI: 922-4,264).ConclusionsIntermittent detection of an absent or abnormal FHR using a fetal stethoscope is associated with FSB, increased need for neonatal resuscitation, BA, and neonatal death in a limited-resource setting. The likelihood of an abnormal FHR is magnified with labor complications.Copyright © 2012 S. Karger AG, Basel.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…