• JAMA network open · Nov 2018

    Assessment of Intensive Care Unit Laboratory Values That Differ From Reference Ranges and Association With Patient Mortality and Length of Stay.

    • Patrick D Tyler, Hao Du, Mengling Feng, Ran Bai, Zenglin Xu, Gary L Horowitz, David J Stone, and Leo Anthony Celi.
    • Department of Emergency Medicine, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
    • JAMA Netw Open. 2018 Nov 2; 1 (7): e184521.

    ImportanceLaboratory data are frequently collected throughout the care of critically ill patients. Currently, these data are interpreted by comparison with values from healthy outpatient volunteers. Whether this is the most useful comparison has yet to be demonstrated.ObjectivesTo understand how the distribution of intensive care unit (ICU) laboratory values differs from the reference range, and how these distributions are related to patient outcomes.Design, Setting, And ParticipantsCross-sectional study of a large critical care database, the Medical Information Mart for Intensive Care database, from January 1, 2001, to October 31, 2012. The database is collected from ICU data from a large tertiary medical center in Boston, Massachusetts. The data are collected from medical, cardiac, neurologic, and surgical ICUs. All patients in the database from all ICUs for 2001 to 2012 were included. Common laboratory measurements over the time window of interest were sampled. The analysis was conducted from March to June 2017.Main Outcomes And MeasuresThe overlapping coefficient and Cohen standardized mean difference between distributions were calculated, and kernel density estimate visualizations for the association between laboratory values and the probability of death or quartile of ICU length of stay were created.ResultsAmong 38 605 patients in the ICU (21 852 [56.6%] male; mean [SD] age, 74.5 [55.1] years), 8878 (23%) had the best outcome (ICU survival, shortest quartile length of stay) and 3090 (8%) had the worst outcome (ICU nonsurvival). Distribution curves based on ICU data differed significantly from the hospital standard range (mean [SD] overlapping coefficient, 0.51 [0.32-0.69]). All laboratory values for the best outcome group differed significantly from those in the worst outcome group. Both the best and worst outcome group curves revealed little overlap with and marked divergence from the reference range.Conclusions And RelevanceThe standard reference ranges obtained from healthy volunteers differ from the analogous range generated from data from patients in intensive care. Laboratory data interpretation may benefit from greater consideration of clinically contextual and outcomes-related factors.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…