• J. Thorac. Cardiovasc. Surg. · Dec 2014

    Comparative Study Observational Study

    The influence of positive end-expiratory pressure on stroke volume variation in patients undergoing cardiac surgery: an observational study.

    • Woon-Seok Kang, Seong-Hyop Kim, Sung Yun Kim, Chung-Sik Oh, Song-Am Lee, and Jun-Seok Kim.
    • Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea; Institute of Biomedical Science and Technology, Konkuk University School of Medicine, Seoul, Korea.
    • J. Thorac. Cardiovasc. Surg.. 2014 Dec 1;148(6):3139-45.

    ObjectivesMeasurements of stroke volume variation for volume management in mechanically ventilated patients are influenced by various factors, such as tidal volume, respiratory rate, and chest/lung compliance. However, research regarding the effect of positive end-expiratory pressure on stroke volume variation is limited.MethodsPatients were divided into responder and nonresponder groups according to the prediction of fluid response by the passive leg raising test and hemodynamic parameters, including stroke volume variation, measured in all patients at the following ventilator settings: (1) conventional ventilation (C), tidal volume 10 mL · kg(-1) with positive end-expiratory pressure settings of 0 (C0), 5 (C5), and 10 cmH2O (C10) and (2) lung protective ventilation (P), tidal volume 6 mL · kg(-1) with positive end-expiratory pressure settings of 0 (P0), 5 (P5), and 10 cmH2O (P10).ResultsRegardless of ventilator setting, stroke volume variation in the responder group had an increasing trend as increased positive end-expiratory pressure level and was significantly higher than in the nonresponder group at each positive end-expiratory pressure level. The area under the curve was (1) 0.899 at C0, 0.942 at C5, and 0.985 at C10; and (2) 0.901 at P0, 0.932 at P5, and 0.947 at P10. Optimal threshold values given by receiver operating characteristic curve analysis were (1) 13.5%, 13.5%, and 14.5%; and (2) 13.5%, 13.5%, and 14.5%, respectively.ConclusionsThe threshold value of stroke volume variation in predicting fluid responsiveness may change when positive end-expiratory pressure 10 cmH2O is applied. This must be considered when stroke volume variation is used to detect the fluid responsiveness to prevent volume overload in this mechanical ventilation setting.Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…