• J. Am. Coll. Cardiol. · Jun 2011

    Randomized Controlled Trial Multicenter Study Comparative Study

    Reverse remodeling and the risk of ventricular tachyarrhythmias in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy).

    • Alon Barsheshet, Paul J Wang, Arthur J Moss, Scott D Solomon, Amin Al-Ahmad, Scott McNitt, Elyse Foster, David T Huang, Helmut U Klein, Wojciech Zareba, Michael Eldar, and Ilan Goldenberg.
    • Cardiology Division, University of Rochester Medical Center, Rochester, New York 14642, USA. alon.barsheshet@heart.rochester.edu
    • J. Am. Coll. Cardiol. 2011 Jun 14; 57 (24): 2416-23.

    ObjectivesWe aimed to evaluate the relationship between echocardiographic response to cardiac resynchronization therapy (CRT) and the risk of subsequent ventricular tachyarrhythmias (VTAs).BackgroundCurrent data regarding the effect of CRT on the risk of VTA are limited and conflicting.MethodsThe risk of a first appropriate implantable cardioverter-defibrillator (ICD) therapy for VTA (including ventricular tachycardia, ventricular fibrillation, and ventricular flutter) was compared between high- and low-echocardiographic responders to CRT defibrillator (CRT-D) therapy (defined as ≥ 25% and <25% reductions, respectively, in left ventricular end-systolic volume [LVESV] at 1 year compared with baseline) and ICD-only patients enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy).ResultsThe cumulative probability of a first VTA at 2 years after assessment of echocardiographic response was highest among low responders to CRT-D (28%), intermediate among ICD-only patients (21%), and lowest among high responders to CRT-D (12%), with p < 0.001 for the overall difference during follow-up. Multivariate analysis showed that high responders to CRT-D experienced a significant 55% reduction in the risk of VTA compared with ICD-only patients (p < 0.001), whereas the risk of VTA was not significantly different between low responders and ICD-only patients (hazard ratio [HR]: 1.26; p = 0.21). Consistently, assessment of response to CRT-D as a continuous measure showed that incremental 10% reductions in left ventricular end-systolic volume were associated with corresponding reductions in the risk of subsequent VTA (HR: 0.80; p < 0.001), VTA/death (HR: 0.79; p < 0.001), ventricular tachycardia (HR: 0.80; p < 0.001), and ventricular fibrillation/ventricular flutter (HR: 0.75; p = 0.044).ConclusionsIn patients with left ventricular dysfunction enrolled in the MADIT-CRT trial, reverse remodeling was associated with a significant reduction in the risk of subsequent life-threatening VTAs. (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.