• Europace · Jul 2015

    Randomized Controlled Trial Multicenter Study

    Time-dependent risk reduction of ventricular tachyarrhythmias in cardiac resynchronization therapy patients: a MADIT-RIT sub-study.

    • Martin Stockburger, Arthur J Moss, Brian Olshansky, Helmut Klein, Scott McNitt, Claudio Schuger, James P Daubert, Ilan Goldenberg, Anne-Christine H Ruwald, Bela Merkely, Wojciech Zareba, and Valentina Kutyifa.
    • Experimental and Clinical Research Center, a Joint Cooperation Between the Charité Medical Faculty and the Max-Delbrueck Center for Molecular Medicine, Berlin, Germany Havelland Kliniken, Nauen, Germany.
    • Europace. 2015 Jul 1; 17 (7): 1085-91.

    AimsData on the time-dependent benefit of cardiac resynchronization therapy with defibrillator (CRT-D) compared with a dual-chamber implantable cardioverter-defibrillator (ICD) to reduce death or ventricular tachycardia (VT) or ventricular fibrillation (VF) are limited. We aimed to evaluate the time-related risk of death or sustained VT or VF in patients receiving CRT-D vs. ICD in the MADIT-RIT trial.Methods And ResultsKaplan-Meier survival analyses and multivariate Cox regression models were utilized to compare the incidence and the risk of death or sustained VT/VF in the CRT-D and ICD subgroups by the elapsed time after device implantation (6 months). Of the ICD (n = 742) and CRT-D (n = 757) patients enrolled, the risk of death was lower in CRT-D vs. in ICD early after device implantation [hazard ratio (HR) = 0.42, 95% confidence interval (CI): 0.17-1.03, P = 0.058] and beyond 6 months of follow-up (HR = 0.39, 95% CI: 0.21-0.73, P = 0.004), with the 6-month interaction P = 0.899. The overall risk of sustained VT/VF was reduced in CRT-D vs. ICD patients (HR = 0.73, 95% CI: 0.52-1.03, P = 0.07). However, the risk was similar in the first 6 months (HR = 1.00, 95% CI: 0.62-1.62, P = 0.988), and a lower risk emerged 6 months after CRT-D implantation (HR = 0.58, 95% CI: 0.38-0.88, P = 0.011), with the 6-month interaction P = 0.059.ConclusionThe reduced mortality risk of CRT-D compared with an ICD alone began early after device implantation and was sustained during long-term follow-up; the reduced risk for ventricular tachyarrhythmias did not emerge until 6 months after device implantation.Clinical Trial Registrationhttp://clinicaltrials.gov/ct2/show/NCT00947310.Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…