• Investigative radiology · Nov 1980

    Effects of contrast materials on left ventricular function.

    • C B Higgins.
    • Invest Radiol. 1980 Nov 1; 15 (6 Suppl): S220-31.

    AbstractThe effects of intracoronary administration of contrast materials were investigated in conscious and anesthetized dogs prepared with pressure gauges or catheters in the left ventricle for measuring aortic pressure (P), LVP, and dP/dt, and dimension crystals on opposing endocardial surfaces of the LV for measuring LV dimensions and its first derivative dD/dt (velocity of contraction). All contrast materials were tested at a concentration of 370 mg I/ml. Biphasic responses were observed with monomeric contrast materials; direct effects occurred within the first 10 seconds after injection, while secondary or indirect effects (reflex?) ensued near the end of the first 10 seconds or in the second 10-second period (Higgins, 1978). The standard sodium-containing monomeric contrast material caused decreases in LV peak systolic pressure (LVSP), peak dP/dt, dP/dt at an LVP of 40 mmHg (dP/dt40), peak -dP/dt, -dP/dt at an LVP of 50 mmHg (-dP/dt50), and dD/dt (Higgins, 1978, Newell, 1979). It caused increases in LV end-systolic and end-diastolic dimension. The decreases in -dP/dt (rate of relaxation) persisted during the second 10 seconds, when the parameter of LV contractile state had increased above control levels. Similar effects were observed in the presence of regional myocardial ischemia. Monomeric ionic material with added calcium ions (Isopaque 370) caused initial and secondary increases in LVSP and indexes of LV contractile state but still produced decreases in LV relaxation rate (-dP/dt50). Standard monomeric materials caused a decline in Ca++ of coronary sinus blood concomitant with the depression in LV contractile state, while the calcium-containing material produced an increase in Ca++ in association with the enhancement in LV contractile state (Higgins, 1978). Several nonionic materials also have been tested in this preparation: metrizamide, P-297, and iopamidol. These materials had similar effects on LV function; each caused a slight increase or no change in indexes of LV contractile state and no change in LV dimensions. A new monacid dimer (P-286) with a lower sodium content than monomeric materials produced effects on LV function which were less deleterious than standard monomeric materials, but more so than the nonionic materials.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.