• Eur Heart J Cardiovasc Imaging · Dec 2013

    Comparative Study

    Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: comparison with two-dimensional speckle tracking and relationship with clinical variables.

    • Jose Angel Urbano-Moral, Jose Antonio Arias-Godinez, Raabia Ahmad, Rabiya Malik, Michael S Kiernan, David DeNofrio, Natesa G Pandian, and Ayan R Patel.
    • The Cardiovascular Imaging and Hemodynamic Laboratory, Tufts Medical Center, 800 Washington Street, #32, Boston, MA 02111, USA.
    • Eur Heart J Cardiovasc Imaging. 2013 Dec 1; 14 (12): 1167-73.

    AimsTwo-dimensional speckle-tracking echocardiography (2D-STE) is limited by its inability to track tissue motion in three dimensions. This is particularly relevant in heart transplant recipients, in whom marked translational motion of the transplanted heart is present. We aimed to compare 3-dimensional (3D)- and 2D-STE-derived strain parameters, and to identify clinical features associated with myocardial mechanics in transplant recipients.Methods And ResultsIn 36 heart transplant recipients, global and regional left-ventricular (LV) longitudinal and circumferential strain (LSt and CSt), and radial displacement (RDisp) were obtained by 3D- and 2D-STE, and their results were compared. 3D-STE deformation from a subset of transplant recipients with preserved ejection fraction was compared with a control group of 25 subjects matched by gender, age, history of hypertension, and ejection fraction. Associations between global LSt and CSt and clinical, echocardiographic, and haemodynamic parameters in transplant recipients were investigated. 3D-STE yielded lower magnitude of global LSt compared with 2D-STE (-13 ± 3 vs. -16 ± 3%, P < 0.001). The inferolateral wall was a source of variation between 3D- and 2D-STE both for LSt and CSt. Inferolateral wall 3D-STE-derived RDisp was greater than that observed in control subjects (7.4 ± 1.2 vs. 6.5 ± 1.7 mm, P = 0.03), while anteroseptal RDisp was lower than controls (4.2 ± 1.0 vs. 7.3 ± 1.6 mm, P < 0.001). Multiple regression analysis demonstrated that 3D-STE-derived LSt was independently associated with NYHA class (P < 0.001), while 2D-STE-derived LSt was not.ConclusionExamination of LV mechanics by 3D- and 2D-STE deformation parameters in heart transplant recipients yields significantly discordant results. 3D-STE-derived LSt is independently associated with NYHA class, suggesting a clinically important relationship between functional status and myocardial mechanics.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…