-
- Zareena Shaik and Santhi Sree Mulam.
- Department of Anaesthesiology, Siddhartha Medical College, Vijayawada, Andhra Pradesh, India.
- Anesth Essays Res. 2019 Apr 1; 13 (2): 248-253.
IntroductionFunctional hemodynamic monitoring using dynamic parameters such as stroke volume variations (SVVs) based on pulse contour analysis is considered more accurate than central venous pressure and mean arterial pressure (MAP) in predicting fluid responsiveness. New device, i.e., Vigileo system, allows automatic and continuous monitoring of cardiac output (CO) based on pulse contour analysis and respiratory stroke volume.AimThe study aims to test the above hypothesis using graded volume loading step (VLS) to assess the accuracy of SVV as a predictor of fluid responsiveness in patients undergoing intracranial surgery.Materials And MethodsAfter taking ethical committee approval and informed consent, 60 patients aged between 18 and 55 years belonging to the American Society of Anesthesiologists physical status Class I and II, of either sex, scheduled for brain surgery were included in the study. In this study, 5 min after intubation, with stable hemodynamics, patients received volume loading in successive steps (VLS) of 200 ml of lactated Ringer's solution until the stroke volume increased to <10%. Blood pressure (BP), heart rate (HR), stroke volume (SV), and SVV were measured before and after each VLS. Optimal preload augmentation required by each patient was measured by the number of VLS after which an increase in SV was <10%.ResultsThere was a significant decrease in the baseline BP and SV in responsive and nonresponsive groups for the first VLS, but there is no change in HR statistically. There was a significant change in SV after first VLS. Receiver operating characteristic analysis showed a larger area under the curve of 0.758 for SVV compared to other measured variables. The median number of VLS administered were 2 per patient equating to a mean ± SD requirement of 368 ± 176 ml of crystalloid per patient as the optimal preoperative infusion volume.ConclusionSVV is a better predictor of preload responsiveness measured with third-generation Vigileo device when compared to BP and HR.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.