-
Randomized Controlled Trial Comparative Study
A pilot study comparing three bend angles for lighted stylet intubation.
- Dongwook Won, Jung-Man Lee, Jiwon Lee, Jin-Young Hwang, Tae Kyong Kim, Jee-Eun Chang, Hyerim Kim, Seoyoung Ma, and Seong-Won Min.
- Department of Anesthesiology and Pain Medicine, Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul National University College of Medicine, 20 Boramae-ro 5-gil, Dongjak-gu, 07061, Seoul, Republic of Korea.
- BMC Anesthesiol. 2021 May 17; 21 (1): 148.
BackgroundFor successful lighted stylet intubation, bending the lighted stylet with an appropriate angle is a prerequisite. The purpose of this study was to compare three different bend angles of 70, 80, and 90 degrees for lighted stylet intubation.MethodsThe patient trachea was intubated with a lighted stylet bent at 70, 80, or 90 degrees according to the randomly allocated groups (group I, II, and III, respectively). A lighted stylet combined with a tracheal tube was prepared with a bend angle of 70, 80, or 90 degrees according to the assigned group. We checked the success rate at the first attempt and overall success rate for the two attempts. Additionally, we measured search time, which was time from insertion of the bent union into the patient mouth to the start of advancing the tracheal tube while separating it from the lighted stylet, and evaluated postoperative sore throat (POST) at 2, 4, and 24 h after the recovery from anesthesia.ResultsThere was no statistically significant difference between group I, II, and III for success rate at first attempt (73.9 %, 88.2 %, and 94.7 %, respectively, p = 0.178), even though there was a trend of increasing success rate with increasing bend angles. For overall success rate, there was similar result to that in the first attempt between the groups I, II, and III (82.6 %, 94.1 %, and 100 %, respectively, p = 0.141). However, search time took significantly longer in group I than groups II and III (p < 0.001). When group II and III were compared for POST with numeric rating scale (0-10), it was significantly lower in group II than III at 2, 4 h after the recovery (0.5 vs. 2.3, p = 0.016, and 0.4 vs. 1.8, p = 0.011, respectively).ConclusionsThe bend angle of the lighted stylet affected the time required for tracheal intubation and POST in our study. 80 and 90 degrees as a bend angle seem to be acceptable for clinicians in regard to success rate of lighted stylet intubation. Considering the success rate of lighted stylet intubation and POST, the bend angle of 80 degrees might be better than 70 and 90 degrees.Trial RegistrationClinicalTrials.gov Identifier NCT03693235 , registered on 30 September 2018.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.