• J. Cardiovasc. Electrophysiol. · Feb 2007

    Multicenter Study Comparative Study

    Acute evaluation of programmer-guided AV/PV and VV delay optimization comparing an IEGM method and echocardiogram for cardiac resynchronization therapy in heart failure patients and dual-chamber ICD implants.

    • James H Baker, John McKenzie, Scott Beau, G Stephen Greer, James Porterfield, Matthew Fedor, Steven Greenberg, Emile G Daoud, Raffaele Corbisiero, J Russell Bailey, and Linda Porterfield.
    • St. Thomas Hospital, Nashville, Tennessee, USA. jbaker@heartgroup.net
    • J. Cardiovasc. Electrophysiol. 2007 Feb 1; 18 (2): 185-91.

    IntroductionIntracardiac delay optimization of biventricular and dual-chamber pacing devices currently relies on time-consuming echocardiographic measurements. A novel intracardiac electrogram (IEGM) method for atrioventricular (AV/PV) and interventricular (VV) delay optimization was developed, which can be performed during routine device follow-up.Methods And ResultsIn this prospective, nonrandomized, multi-center trial, patients previously implanted with St. Jude Medical cardiac resynchronization therapy defibrillator (CRT-D) devices or dual-chamber implantable cardioverter defibrillators (ICDs) underwent standard AV/PV and/or VV delay optimization guided by Doppler echocardiogram measurements of the maximum aortic velocity time integral (aortic VTI). Aortic VTI measurements applying the IEGM method recommended delays were then obtained in all patients. Fifty-eight patients (age: 68 +/- 11 years; 81% male; 74% ischemic) and 57 patients (age: 71 +/- 10 years; 74% male; 71% ischemic) were enrolled for AV/PV and VV delay evaluation, respectively. An independent core lab determined the maximum aortic VTIs. Data analysis of the AV, PV, and VV delays demonstrated the concordance correlation coefficient (CCC) between the standard method aortic VTI values and the IEGM method aortic VTI values was 97.5%, 96.1%, and 96.6%, respectively. All analyses demonstrated that the CCC > 90% (P < 0.05).ConclusionThe automated programmer-based IEGM method provides a reliable and simpler alternative to standard techniques for the optimization of AV/PV and VV delay settings in patients with CRT-D devices and dual-chamber ICDs.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…