-
Comparative Study
Effect of fibrin sealant in positioning and stabilizing microvascular pedicle: A comparative study.
- Jeong Tae Kim, Youn Hwan Kim, and Sang Wha Kim.
- Department of Plastic and Reconstructive Surgery, College of Medicine, Hanyang University, Seoul, Korea.
- Microsurgery. 2017 Jul 1; 37 (5): 406-409.
IntroductionFibrin sealants have had applications in hemostasis, cohesion, and promotion of healing in plastic surgery. In this article, we review cases where fibrin sealant was used to stabilize microvascular pedicles and compared with previous free flaps performed without fibrin sealant.MethodsBetween 2008 and 2010, 62 consecutive patients underwent free tissue transfer for reconstruction; this involved 33 latissimus dorsi perforator flaps, 14 thoracodorsal artery perforator flaps, 9 latissimus dorsi myocutaneous flaps, 3 lateral thoracic artery perforator flaps, and 3 transverse rectus abdominis myocutaneous flaps, used in head and neck reconstruction, lower limb reconstructions, breast reconstructions, and facial palsy reconstruction. Following microvascular anastomosis, the microvascular pedicles were placed in the optimal position, and fibrin sealant was used to fix and stabilize them. The complications, such as venous thrombosis, arterial thrombosis, hematoma, and vascular pedicle kinking, were compared with that of 672 previous free flaps without fibrin sealant for stabilizing microvascular pedicles.ResultsAmong the 62 free tissue transfers using fibrin sealant, there was only one complication involving flap failure (1.6%), in this case due to venous thrombosis. Analysis of 672 free flaps performed without application of fibrin sealant revealed 24 complications (3.6%), due to 3 venous thrombosis, 1 arterial thrombosis, 4 vascular pedicel compression due to hematoma, and 16 pedicle kinking. However, the comparison of complications between the free flap using fibrin sealant and the free flap without fibrin sealant were not statistically significant (P = 0.65).ConclusionsFibrin sealant can be used to prevent vascular kinking and to position anastomosed vessels after successful micro-anastomosis and allow the reconstructive surgeon to overcome challenging situations of vascular pedicle related complications © 2016 Wiley Periodicals, Inc. Microsurgery 37:406-409, 2017.© 2016 Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.