BMJ quality & safety · Dec 2015
Observational StudyExpanding the scope of Critical Care Rapid Response Teams: a feasible approach to identify adverse events. A prospective observational cohort.
- Andre Carlos Kajdacsy-Balla Amaral, Andrew McDonald, Natalie G Coburn, Wei Xiong, Kaveh G Shojania, Robert A Fowler, Martin Chapman, and Neill K J Adhikari.
- Interdepartmental Division of Critical Care, University of Toronto, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
- BMJ Qual Saf. 2015 Dec 1; 24 (12): 764-8.
IntroductionAdverse events (AEs) affect 3-12% of hospitalised patients. These are estimates from a labour-intensive chart review process,which is not feasible outside research. Clinical deterioration on the wards triggers a rapid response teams (RRTs) consult and can be used to identify an AE prospectively.ObjectivesTo demonstrate the feasibility of using RRT to detect AEs and compare this methodology to the rates reported using an electronic safety reporting system.MethodsProspective observational cohort of RRT consults. Three independent physicians reviewed all cases for the occurrence of an AE and its preventability. We summarise AEs as rates per 1000 patient-days, and compared the rates between RRT and the safety reporting system using a Poisson model.ResultsThere were 8713 hospital admissions, with 531 RRT consults and 247 (2.8%) cases included. Forty-four (17.8%) and 35 cases (14.2%) were judged as AEs and preventable AEs, respectively. RRT identified 0.52 AE/1000 patient-days, compared with 0.21 AE/1000 patient-days detected through the electronic safety reporting system (rate ratio 2.4, 95% CI 1.4 to 4.2, p=0.0014). Patients in surgical wards had more AEs (0.83/1000 vs 0.36/1000, p<0.01) and preventable AEs (0.70 vs 0.21, p<0.01) than patients in medical wards. Agreement for AE (κ 0.46, 95% CI 0.39 to 0.53) and preventable AE (κ 0.47, 95% CI 0.40 to 0.53) was moderate among reviewers.ConclusionsReviewing RRT consults identified a high proportion of AEs and preventable AEs. This methodology detected twice as many AEs as the hospital's safety reporting system. RRT clinicians provide a complementary and more sensitive mechanism than traditional safety reporting systems to identify possible AEs in hospitals.Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.