• J Am Heart Assoc · Oct 2017

    Comparative Study Observational Study

    Cardiac Resynchronization Therapy Using Quadripolar Versus Non-Quadripolar Left Ventricular Leads Programmed to Biventricular Pacing With Single-Site Left Ventricular Pacing: Impact on Survival and Heart Failure Hospitalization.

    • Francisco Leyva, Abbasin Zegard, Tian Qiu, Edmund Acquaye, Gaetano Ferrante, Jamie Walton, and Howard Marshall.
    • Aston Medical Research Institute, Aston Medical School, Aston University, Birmingham, United Kingdom f.leyva@aston.ac.uk.
    • J Am Heart Assoc. 2017 Oct 17; 6 (10).

    BackgroundIn cardiac resynchronization therapy (CRT), quadripolar (QUAD) left ventricular (LV) leads are less prone to postoperative complications than non-QUAD leads. Some studies have suggested better clinical outcomes.Methods And ResultsClinical events were assessed in 847 patients after CRT-pacing or CRT-defibrillation using either QUAD (n=287) or non-QUAD (n=560), programmed to single-site site LV pacing. Over a follow-up period of 3.2 years (median [interquartile range, 1.90-5.0]), QUAD was associated with a lower total mortality (adjusted hazard ratio [aHR]: 0.32, 95% confidence interval [CI], 0.20-0.52), cardiac mortality (aHR: 0.36, 95% CI, 0.20-0.65), and heart failure (HF) hospitalization (aHR: 0.62, 95% CI, 0.39-0.99), after adjustment for age, sex, New York Heart Association class, HF etiology, device type (CRT-pacing or CRT-defibrillation), comorbidities, atrial rhythm, medication, left ventricular ejection fraction, and creatinine. Death from pump failure was lower with QUAD (aHR: 0.33; 95% CI, 0.18-0.62), but no group differences emerged with respect to sudden cardiac death. There were no differences in implant-related complications. Re-interventions for LV displacement or phrenic nerve stimulation, which were lower with QUAD, predicted total mortality (aHR: 1.68, 95% CI, 1.11-2.54), cardiac mortality (aHR: 2.61, 95% CI, 1.66-4.11) and HF hospitalization (aHR: 2.09, 95% CI, 1.22-3.58).ConclusionsCRT using QUAD, programmed to biventricular pacing with single-site LV pacing, is associated with a lower total mortality, cardiac mortality, and HF hospitalization. These trends were observed for both CRT-defibrillation and CRT-pacing, after adjustment for HF cause and other confounders. Re-intervention for LV lead displacement or phrenic nerve stimulation was associated with worse outcomes.© 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…